Picosecond-laser electronic-excitation tagging (PLEET), a seedless picosecond-laser-based velocimetry technique, is demonstrated in non-reactive flows at a repetition rate of 100 kHz with a 1064 nm, 100 ps burst-mode laser. The fluorescence lifetime of the PLEET signal was measured in nitrogen, and the laser heating effects were analyzed. PLEET experiments with a free jet of nitrogen show the ability to measure multi-point flow velocity fluctuations at a 100 kHz detection rate or higher. Both spectral and dynamic mode decomposition analyses of velocity on a Ma=0.8 free jet show two dominant Strouhal numbers around 0.24 and 0.48, respectively, well within the shear-layer flapping frequencies of the free jets. This technique increases the laser-tagging repetition rate for velocimetry to hundreds of kilohertz. PLEET is suitable for subsonic through supersonic laminar- and turbulent-flow velocity measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.42.000239 | DOI Listing |
Krypton Tagging Velocimetry (KTV) and Picosecond Laser Electronic Excitation Tagging (PLEET) velocimetry at a 100-kHz rate were demonstrated in Mach 18 flow conditions at the Arnold Engineering Development Center (AEDC) Tunnel 9 employing a burst-mode laser system and a custom optical parametric oscillator (OPO). The measured freestream flow velocities from both KTV and PLEET agreed well with the theoretical calculation. The increase in repetition rate provides better capability to perform time-resolved velocimetry measurements in hypersonic flow environments.
View Article and Find Full Text PDFNonintrusive three-component (3C) velocity measurements of free jet flows were conducted by stereoscopic picosecond laser electronic excitation tagging (S-PLEET) at 100 kHz. The fundamental frequency of the burst-mode laser at 1064 nm was focused to generate the PLEET signal in a free jet flow. A stereoscopic imaging system was used to capture the PLEET signals.
View Article and Find Full Text PDFDetailed characterizations of picosecond laser electronic excitation tagging (PLEET) in pure nitrogen () and air with a 24 ps burst-mode laser system have been conducted. The burst-mode laser system is seeded with a 200 fs broadband seeding laser to achieve short pulse duration. As a non-intrusive molecular tagging velocimetry (MTV) technique, PLEET achieves "writing" via photo-dissociating nitrogen molecules and "tracking" by imaging the molecular nitrogen emissions.
View Article and Find Full Text PDFChemphyschem
November 2020
School of Chemistry, The University of Nottingham, University Park, Nottingham, NG7 2RD, U.K.
The VUV absorption spectrum of fenchone is re-examined using synchrotron radiation Fourier transform spectrometry, revealing new vibrational structure. Picosecond laser (2+1) resonance enhanced multiphoton ionization (REMPI) spectroscopy complements this, providing an alternative view of the 3spd Rydberg excitation region. These spectra display broadly similar appearance, with minor differences that are largely explained by referring to calculated one- and two-photon electronic excitation cross-sections.
View Article and Find Full Text PDFPicosecond laser electronic-excitation tagging (PLEET) was demonstrated in a Mach-6 Ludwieg tube at a repetition rate of 100 kHz using a 1064 nm, 100 ps burst-mode laser. The system performance of high-speed velocimetry in unseeded air and nitrogen Mach-6 flows at a static pressure in the range of 5-20 torr were evaluated. Based on time-resolved freestream flow measurements and computational fluid dynamics (CFD) calculations, we concluded that the measurement uncertainty of 100 kHz PLEET measurement for Mach 6 freestream flow condition is ∼1%.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!