Aims: To determine the incidence, risk factors, and mortality of infective endocarditis (IE) following implantation of a first-time, permanent, cardiac implantable electronic device (CIED).

Methods And Results: From Danish nationwide administrative registers (beginning in 1996), we identified all de-novo permanent pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) together with the occurrence of post-implantation IE-events in the period from 2000-2012. Included were 43 048 first-time PM/ICD recipients. Total follow-up time was 168 343 person-years (PYs). The incidence rate (per 1000 PYs) of IE in PM was 2.1 (95% confidence interval [CI]: 1.7-2.6) for single chamber devices and 6.2 (95% CI: 4.5-8.7) for cardiac resynchronization therapy (CRT); similarly, the rate of IE in ICD was 3.7 (95% CI: 2.9-4.7) in single chamber devices and 6.3 (95% CI: 4.4-9.0) in CRT. In multivariable analysis, increased PM complexity served as independent risk factor for IE {dual chamber PM [hazard ratio (HR) 1.39; 95% CI: 1.07-1.80] and CRT [HR: 1.84; 95% CI: 1.20-2.84]}. During follow-up, generator replacement (HR: 2.79; 95% CI: 1.87-4.17) and lead revision (HR: 4.33; 95% CI: 3.25-5.78) in PMs were associated with increased risk. Corresponding estimates in ICDs were 2.49 (95% CI: 1.28-4.86) and 6.58 (95% CI: 4.49-9.63). Risk of death after IE was significantly increased in PM and ICD with HRs of 1.56 (95% CI: 1.33-1.82) and 2.63 (95% CI: 2.00-3.48), respectively.

Conclusion: The risk of IE increased with increasing PM complexity. Other important risk factors were subsequent generator replacement and lead revision. IE was associated with an increased risk of mortality in the area of CIED.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euw404DOI Listing

Publication Analysis

Top Keywords

95%
12
infective endocarditis
8
risk
8
risk death
8
cardiac implantable
8
implantable electronic
8
electronic device
8
risk factors
8
single chamber
8
chamber devices
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!