Comparison of the i-gel and other supraglottic airways in adult manikin studies: Systematic review and meta-analysis.

Medicine (Baltimore)

Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul, Republic of Korea.

Published: January 2017

Background: The i-gel has a gel-like cuff composed of thermoplastic elastomer that does not require cuff inflation. As the elimination of cuff inflation may shorten insertion time, the i-gel might be a useful tool in emergency situations requiring prompt airway care. This systematic review and meta-analysis of previous adult manikin studies for inexperienced personnel was performed to compare the i-gel with other supraglottic airways.

Methods: We searched PubMed, the Cochrane Library, and EMBASE for eligible randomized controlled trials (RCTs) published before June 2015, including with a crossover design, using the following search terms: "i-gel," "igel," "simulation," "manikin," "manikins," "mannequin," and "mannequins." The primary outcomes of this review were device insertion time and the first-attempt success rate of insertion.

Results: A total of 14 RCTs were included. At the initial assessment without difficult circumstances, the i-gel had a significantly shorter insertion time than the LMA Classic, LMA Fastrach, LMA Proseal, LMA Unique, laryngeal tube, Combitube, and EasyTube. However, a faster insertion time of the i-gel was not observed in comparisons with the LMA Supreme, aura-i, and air-Q. In addition, the i-gel did not show the better results for the insertion success rate when compared to other devices.

Conclusion: The findings of this meta-analysis indicated that inexperienced volunteers placed the i-gel more rapidly than other supraglottic airways with the exception of the LMA Supreme, aura-i, and air-Q in manikin studies. However, the quicker insertion time is clinically not relevant. The unapparent advantage regarding the insertion success rate and the inherent limitations of the simulation setting indicated that additional evidence is necessary to confirm these advantages of the i-gel in an emergency setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5228692PMC
http://dx.doi.org/10.1097/MD.0000000000005801DOI Listing

Publication Analysis

Top Keywords

insertion time
20
manikin studies
12
success rate
12
i-gel supraglottic
8
supraglottic airways
8
adult manikin
8
systematic review
8
review meta-analysis
8
i-gel
8
cuff inflation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!