A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Solid-Phase Extraction and HPLC Method for Simultaneous Estimation of Ilaprazole and Glimepiride in Rat Plasma: Application to Pharmacokinetic Studies. | LitMetric

A novel, simple and mass spectrometry (MS) compatible high-performance liquid chromatography (HPLC) method is reported for the simultaneous estimation of ilaprazole (ILA) and glimepiride (GLM) in rat plasma. The bio-analytical procedure involves extraction of ILA, GLM and internal standard (IS) from rat plasma with a solid-phase extraction (SPE) process. The chromatographic analysis was performed on Waters-600 system using an isocratic mobile phase comprising methanol:water (80:20 % v/v) with pH of water modified to three using formic acid at a flow rate of 1.0 mL/min and Kinetex C18 column maintained at 30 ± 1°C. The signals were monitored using a PDA detector set at 225 nm. IS, ILA and GLM eluted at 2.04, 4.7 and 7.4 min, respectively, and the total run time was 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 10-600 ng/mL (r2 = 0.999). The intra- and inter-day precisions for ILA and GLM were (%RSD values) in the range of 1.52-9.74 and 1.52-11.76%, respectively, in rat plasma. The method was successfully applied in pharmacokinetic studies followed by oral administration of GLM and ILA in rats.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmw189DOI Listing

Publication Analysis

Top Keywords

rat plasma
16
ila glm
12
solid-phase extraction
8
hplc method
8
simultaneous estimation
8
estimation ilaprazole
8
pharmacokinetic studies
8
ila
5
glm
5
development solid-phase
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!