Purpose: To evaluate magnetization-prepared 3D T -weighted magnetic resonance imaging (MRI) measurements of acute tissue changes produced during ablative MR high-intensity focused ultrasound (MR-HIFU) exposures.
Materials And Methods: A clinical MR-HIFU system (3T) was used to generate thermal lesions (n = 24) in the skeletal muscles of three pigs. T -weighted, 2D T -weighted, and magnetization-prepared 3D T -weighted sequences were acquired before and after therapy to evaluate tissue changes following ablation. Tissues were harvested shortly after imaging, fixed in formalin, and gross-sectioned. Select lesions were processed into whole-mount sections. Lesion dimensions for each imaging sequence (length, width) and for gross sections (diameter of lesion core and rim) were assessed by three physicists. Contrast-to-background ratio between lesions and surrounding muscle was compared.
Results: Lesion dimensions on T and 2D T -weighted imaging sequences were well correlated (R ∼0.7). The contrast-to-background ratio between lesion and surrounding muscle was 7.4 ± 2.4 for the magnetization-prepared sequence versus 1.7 ± 0.5 for a conventional 2D T -weighted acquisition, and 7.0 ± 2.9 for a contrast-enhanced T -weighted sequence. Compared with diameter measured on gross pathology, all imaging sequences overestimated the lesion core by 22-33%, and underestimated the lesion rim by 6-13%.
Conclusion: After MR-HIFU exposures, measurements of the acute thermal damage patterns in muscle using a magnetization-prepared 3D T -weighted imaging sequence correlate with 2D T -weighted and contrast-enhanced T -weighted imaging, and all agree well with histology. The magnetization-prepared sequence offers positive tissue contrast and does not require IV contrast agents, and may provide a noninvasive imaging evaluation of the region of acute thermal injury at multiple times during HIFU procedures.
Level Of Evidence: 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:354-364.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5502206 | PMC |
http://dx.doi.org/10.1002/jmri.25605 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!