Responses of Human Neonates to Highly Diluted Odorants from Sweat.

J Chem Ecol

Developmental Ethology and Cognitive Psychology Group, Centre des Sciences du Goût et de l'Alimentation, CNRS-Université de Bourgogne, 9E bd Jeanne d'Arc, 21000, Dijon, France.

Published: January 2017

Conjugated forms of odorants contributing to sweat odor occur not only in human sweat but also in amniotic fluid, colostrum, and milk. However, it is unclear whether the released odorants are detected and hedonically discriminated by human newborns. To investigate this issue, we administered highly diluted solutions of (R)/(S)-3-methyl-3-sulfanylhexan-1-ol (MSH), (R)/(S)-3-sulfanylhexan-1-ol (SH), (E)/(Z)-3-methylhex-2-enoic acid (3M2H), and (R)/(S)-3-hydroxy-3-methylhexanoic acid (HMHA) to 3-d-old infants while their respiratory rate and oro-facial movements were recorded. Adult sensitivity to these odorants was assessed via triangle tests. Whereas no neonatal stimulus-specific response was found for respiratory rate, oro-facial reactivity indicated orthonasal detection of MSH and SH by male neonates, and of HMHA by the whole group of neonates. Dependent on the dilution of odorants, newborns evinced neutral responses or longer negative oro-facial expressions compared with the reference stimuli. Finally, newborns appeared to be more sensitive to the target odorants than did adults.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10886-016-0804-xDOI Listing

Publication Analysis

Top Keywords

highly diluted
8
respiratory rate
8
rate oro-facial
8
odorants
6
responses human
4
human neonates
4
neonates highly
4
diluted odorants
4
odorants sweat
4
sweat conjugated
4

Similar Publications

Highly Tension-Strained Copper Concentrates Diluted Cations for Selective Proton-Exchange Membrane CO2 Electrolysis.

Angew Chem Int Ed Engl

January 2025

University of Science and Technology of China, Division of Nanomaterials & Chemistry, Hefei National Laboratory for Physical Sciences at Microscale, CHINA.

Electrolysis of carbon dioxide (CO2) in acid offers a promising route to overcome CO2 loss in alkaline and neutral electrolytes, but requires concentrated alkali cations (typical ≥3 M) to mitigate the trade-off between low pH and high hydrogen evolution reaction (HER) rate, causing salt precipitation. Here we report a strategy to resolve this problem by introducing tensile strain in a copper (Cu) catalyst, which can selectively reduce CO2 to valuable multicarbon products, particularly ethylene, in a pH 1 electrolyte with 1 M potassium ions. We find that the tension-strained Cu creates an electron-rich surface that concentrates diluted potassium ions, contributing to CO2 activation and HER suppression.

View Article and Find Full Text PDF

Background: Effective hemorrhage protocols prioritize immediate hemostatic resuscitation to manage hemorrhagic shock. Prehospital resuscitation using blood products, such as whole blood or alternatively dried plasma in its absence, has the potential to improve outcomes in hemorrhagic shock patients. However, integrating blood products into prehospital care poses substantial logistical challenges due to issues with storage, transport, and administration in field environments.

View Article and Find Full Text PDF

Negative staining electron microscopy is one of the easiest ways to determine the shape and dimensions of multimeric protein complexes over 100 kDa molecular weight. This method requires small volumes (< 10 μL) of dilute protein (0.01-0.

View Article and Find Full Text PDF

Background: Imlifidase is an IgG-cleaving endopeptidase conditionally approved in Europe for desensitization of highly sensitized patients before kidney transplantation. We present 5-y outcomes and donor-specific antibody (DSA) levels for clinical trial participants from a single site who received imlifidase for desensitization before incompatible transplantation (NCT02790437).

Methods: Imlifidase was administered up to 24 h before living or deceased donor kidney transplantation.

View Article and Find Full Text PDF

A rapid and highly sensitive fluorescence immunochromatographic test strip for pepsin detection in human hypopharyngeal saliva.

Anal Methods

January 2025

Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.

Pepsin serves as a potential biomarker for laryngopharyngeal reflux disease (LPRD). The reported methods for detecting pepsin still have limitations, such as long reaction times and low sensitivity. Therefore, it is crucial to develop a rapid, simple and sensitive detection method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!