Osteoporosis is a disease characterized by a degradation of bone structures. Various methods have been developed to diagnose osteoporosis by measuring bone mineral density (BMD) of patients. However, BMDs from these methods were not equivalent and were incomparable. In addition, partial volume effect introduces errors in estimating bone volume from computed tomography (CT) images using image segmentation. In this study, a two-compartment model (TCM) was proposed to calculate bone volume fraction (BV/TV) and BMD from CT images. The TCM considers bones to be composed of two sub-materials. Various equivalent BV/TV and BMD can be calculated by applying corresponding sub-material pairs in the TCM. In contrast to image segmentation, the TCM prevented the influence of the partial volume effect by calculating the volume percentage of sub-material in each image voxel. Validations of the TCM were performed using bone-equivalent uniform phantoms, a 3D-printed trabecular-structural phantom, a temporal bone flap, and abdominal CT images. By using the TCM, the calculated BV/TVs of the uniform phantoms were within percent errors of ±2%; the percent errors of the structural volumes with various CT slice thickness were below 9%; the volume of the temporal bone flap was close to that from micro-CT images with a percent error of 4.1%. No significant difference (p >0.01) was found between the areal BMD of lumbar vertebrae calculated using the TCM and measured using dual-energy X-ray absorptiometry. In conclusion, the proposed TCM could be applied to diagnose osteoporosis, while providing a basis for comparing various measurement methods.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2016.2646698DOI Listing

Publication Analysis

Top Keywords

bone volume
12
two-compartment model
8
bone
8
bone mineral
8
computed tomography
8
tomography images
8
diagnose osteoporosis
8
partial volume
8
image segmentation
8
tcm
8

Similar Publications

Background: Resistance to chemoimmunotherapy in patients with advanced non-small cell lung cancer (NSCLC) necessitates effective prognostic biomarkers. Although F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) has shown potential for efficacy assessment, it has been mainly evaluated in immuno-monotherapy setting, lacking elaborations in the scenarios of immunotherapy combined with chemotherapy. To tackle this dilemma, we aimed to build a non-invasive PET/CT-based model for stratifying tumor heterogeneity and predicting survival in advanced NSCLC patients undergoing chemoimmunotherapy.

View Article and Find Full Text PDF

Objectives Of The Study: (1) To evaluate the effect of platelet-rich fibrin (PRF) with bone marrow aspirate on regenerative capacity in patients undergoing iliac bone grafting for secondary alveolar bone grafting. (2) and to compare it with group 2 where only bone marrow aspirate was used along with iliac bone graft in secondary alveolar bone grafting.

Materials And Methods: A prospective study on patients with cleft alveolus, requiring bone grafting and reporting to our unit from October 2018 to October 2020 was included in this study.

View Article and Find Full Text PDF

Introduction: The tympanic cavity contains three tiny bones, the malleus, incus, and stapes, which have a fundamental role in the transmission of sound. Recent research emphasizes the use of CBCT for the anatomic study of the temporal bone. The information about middle ear anatomy on CBCT scans is meager; hence, this retrospective study was conducted to identify and determine the various morphometrical parameters of the malleus using CBCT which can be helpful during reconstructive procedures for the otologic surgeon.

View Article and Find Full Text PDF

Since the initial publication on the first TiCT MXene in 2011, there has been a significant increase in the number of reports on applications of MXenes in various domains. MXenes have emerged as highly promising materials for various biomedical applications, including photothermal therapy (PTT), drug delivery, diagnostic imaging, and biosensing, owing to their fascinating conductivity, mechanical strength, biocompatibility and hydrophilicity. Through surface modification, MXenes can mitigate cytotoxicity, enhance biological stability, and improve histocompatibility, thereby enabling their potential use in biomedical applications.

View Article and Find Full Text PDF

Study Design: This was a retrospective study.

Purpose: The current study aimed to investigate the clinical efficacy of atlantodentoplasty using the anterior retropharyngeal approach against irreducible atlantoaxial dislocation with atlantodental bony obstruction.

Overview Of Literature: In cases of atlantoaxial dislocation with atlantodental bony obstruction, owing to the presence of an osteogenic mass between the atlas and odontoid process, reduction is challenging to complete using the posterior approach.

View Article and Find Full Text PDF