Aim: To evaluate the effect of instant urinary catheterization on pregnancy rates in women who are on bed rest after embryo transfer (ET).

Methods: This retrospective study included patients who underwent intracytoplasmic sperm injection (ICSI) treatment at the Akdeniz University Fertility Clinic between January 2015 and March 2016. All patients were advised bed rest for an hour after ET. The clinic's electronic database was screened to identify the uterine anatomy of the patients, transferred embryo quality, and urinary catheterization status. Only women with an anteverted and anteflexed uterus and cycles that resulted in high-quality blastocyst transfers were included in this analysis. Finally, 71 cycles with urinary catheterization and 81 cycles with no catheterization were analyzed.

Results: The clinical (53.5 vs. 40.7%, p = 0.115) and ongoing pregnancy (43.7 vs. 35.8%, p = 0.323) rates were comparable between urinary catheterization and non-catheterization groups. Multivariate analysis by logistic regression including confounding factors revealed that urinary catheterization was independently associated with clinical pregnancy (OR 2.06, 95% CI 1.03-4.13, p = 0.041). However, no significant association was detected between catheterization and the clinically more relevant, ongoing pregnancy (OR 1.65, 95% CI 0.82-3.30, p = 0.160).

Conclusion: Our preliminary findings on the use of instant urinary catheterization after ET are promising and justify further investigation in larger prospective studies.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000455045DOI Listing

Publication Analysis

Top Keywords

urinary catheterization
28
instant urinary
12
catheterization
9
catheterization pregnancy
8
intracytoplasmic sperm
8
sperm injection
8
embryo transfer
8
bed rest
8
ongoing pregnancy
8
urinary
6

Similar Publications

The Autologous Fascial Pubovaginal Sling for Recurrent Stress Incontinence: A Retrospective Study.

Low Urin Tract Symptoms

January 2025

Department of Urology, Institute of Urology (Laboratory of Reconstructive Urology), West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.

Aim: This study aimed to analyze the clinical efficacy and safety of autologous fascial pubovaginal sling (AFPVS) surgery in treating recurrent stress urinary incontinence (SUI) following the failure of mid-urethral sling procedures.

Methods: A retrospective analysis was conducted on the clinical data of SUI patients who underwent AFPVS at our hospital between 2008 June and 2024 June following the failure of mid-urethral sling procedures. The analysis included basic information, surgical parameters, and postoperative complications.

View Article and Find Full Text PDF

Introduction: Epidermolysis bullosa (EB) can severely affect the urinary tract, leading to strictures and urine outflow obstruction, which pose significant risks to kidney function. Procedures involving the urinary mucosa often exacerbate these issues, making safe bladder emptying a major challenge. This study reviews surgical methods for managing urological complications in EB patients, with a focus on the Macedo procedure, which offers a promising alternative that avoids further bladder mucosa irritation and prevents disease exacerbation.

View Article and Find Full Text PDF

Introduction: The presence of an artificial urinary sphincter can be overlooked resulting in inadvertent urethral catheterization and cuff erosion. A hard-stop best practice advisory was created in the electronic medical record to alert for the presence of an artificial urinary sphincter. We evaluated its utilization and impact on patient outcomes.

View Article and Find Full Text PDF

Urinary catheters are commonly used in medical practice to drain and monitor urine of patients. However, urinary catheterisation is associated with the risk of developing catheter-associated urinary tract infections (CAUTIs), which can result in life-threatening sepsis that requires antibiotics for treatment. Using the layer-by-layer (LbL) technique, we assembled a multilayer catheter comprising nine quadruple layers (9QL) of alginate, chlorhexidine (CHX), alginate and poly(β-amino ester) (PBAE) built upon an amino-functionalised silicone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!