In this joint theoretical and experimental work, we investigate the properties of Mag-fura-2 and seven structurally related fluorescent sensors designed for the ratiometric detection of Mg cations. The synthesis of three new compounds is described, and the absorption and emission spectra of all of the sensors in both their free and metal-bound forms are reported. A time-dependent density functional theory approach accounting for hydration effects using a hybrid implicit/explicit model is employed to calculate the absorption and fluorescence emission wavelengths, study the origins of the hypsochromic shift caused by metal binding for all of the sensors in this family, and investigate the auxochromic effects of various modifications of the "fura" core. The metal-free forms of the sensors are shown to undergo a strong intramolecular charge transfer upon light absorption, which is largely suppressed by metal complexation, resulting in predominantly locally excited states upon excitation of the metal complexes. Our computational protocol might aid in the design of new generations of fluorescent sensors with low-energy excitation and enhanced properties for ratiometric imaging of metal cations in biological samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.jpcb.6b11045 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Key Laboratory for Special Functional Aggregate Materials of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan, Shandong 250100, China.
The adsorption of DNA probes onto nanomaterials represents a promising bioassay technique, generally employing fluorescence or catalytic activity to generate signals. A significant challenge is maintaining the catalytic activity of chromogenic catalysts during detection while enhancing accuracy by overcoming the limitations of single-signal transmission. This article presents an innovative multimodal analysis approach that synergistically combines the oxidase-like activity of Fe-N-C nanozyme (Fe-NC) with red fluorescent carbon quantum dots (R-CQDs), further advancing the dual-mode analysis method utilizing R-CQDs@Fe-NC.
View Article and Find Full Text PDFAnal Methods
January 2025
Jiangxi University of Chinese Medicine, Nan Chang, Jiangxi 330004, China.
This study reports a novel ratiometric fluorescence sensor based on a tetraphenylethylene-bipyridine covalent organic framework (TPE-Bpy-COF) for the sensitive detection of Cu, leveraging the unique coordination properties of the bipyridine moieties. The interaction between Cu and the nitrogen atoms in the bipyridine units induces fluorescence quenching at 500 nm through an efficient host-guest electron transfer mechanism, where excited-state electrons from the COF framework are transferred to the vacant orbitals of Cu. Upon excitation at 410 nm, the sensor exhibits a primary emission peak at 500 nm, which is quenched in the presence of Cu, while an overtone peak at 820 nm remains stable, serving as an internal reference for ratiometric measurements and significantly enhancing the accuracy and reliability of the sensor.
View Article and Find Full Text PDFPhotochem Photobiol Sci
January 2025
CNRS, Institut des Sciences Moléculaires d'Orsay, Université Paris-Saclay, 91405, Orsay, France.
The precise monitoring of pH is critical in various applications, particularly in biology-related areas. In this work, we report the synthesis and characterization of a novel cyanine-based fluorescent pH sensor with a pK around 6. This pH-sensitive dye features a cyanine chromophore coupled to a piperazine moiety, which modulates the protonation equilibrium and thus the optical response.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Anhui Provincial Key Laboratory of Biomedical Materials and Chemical Measurement, Laboratory of Functionalized Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241002, P. R. China.
HClO is considered a potential contributing factor and biomarker of inflammatory bowel disease (IBD). Accurate monitoring of lysosomal HClO is important for further developing specific diagnostic and therapeutic schedules for IBD. However, only rare types of fluorescent probes have been reported for detecting HClO in IBD so far.
View Article and Find Full Text PDFLangmuir
January 2025
College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou 450046, China.
The development of probes for the efficient detection of volatile organic compounds is crucial for both human health protection and environmental monitoring. In this study, we successfully synthesized a ratiometric fluorescent sensing material [Eu-UiO-67 (1:1)], featuring dual-emission fluorescence peaks via a one-pot method. This material demonstrated exceptional ratiometric fluorescence recognition properties for liquid styrene and isoprene, achieving low limit of detections (LODs) of 6.