A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly sensitive and stable Ag@SiO nanocubes for label-free SERS-photoluminescence detection of biomolecules. | LitMetric

Highly sensitive and stable Ag@SiO nanocubes for label-free SERS-photoluminescence detection of biomolecules.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 106, Taiwan; National Synchrotron Radiation Research Center, Hsin-Chu, Taiwan. Electronic address:

Published: March 2017

Surface-enhanced Raman scattering (SERS) and fluorescence microscopy are a widely used biological and chemical characterization techniques. However, the peak overlapping in multiplexed experiments and rapid photobleaching of fluorescent organic dyes is still the limitations. When compared to Ag nanocubes (NCs), higher SERS sensitivities can be obtained with thin shelled silica Ag@SiO NCs, in contrast metal-enhanced photoluminescence (MEPL) is only found with NCs that have thicker silica shells. A 'dual functionality' represented by the simultaneous strengthening of SERS and MEPL signals can be achieved by mixing Ag@SiO NCs, with a silica shell thickness of ~1.5nm and ~4.4nm. This approach allows both the Ag@SiO NCs SERS and MEPL sensitivities to be maintained at ~90% after 12weeks of storage. Based on the distinguished detection of creatinine and flavin adenine dinucleotide in the mixture, the integration of SERS and MEPL together on a stable single plasmonic nanoparticle platform offers an opportunity to enhance both biomarker detection sensitivity and specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2016.12.024DOI Listing

Publication Analysis

Top Keywords

ag@sio ncs
12
sers mepl
12
sers
5
ncs
5
highly sensitive
4
sensitive stable
4
ag@sio
4
stable ag@sio
4
ag@sio nanocubes
4
nanocubes label-free
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!