Background: Most skin defects that require reconstruction with a local skin flap have a circular- or oval-shaped pattern. The majority of the skin flaps are planned in an angled shape. Therefore, it may be necessary to modify the shape of the defect or the distal flap border to minimize tissue distortion. We have designed a circular-shaped advancement flap to be compatible with the circular defect.

Methods: Eighteen cases of reconstruction of skin defects in the face, chest wall, hand and buttock area were performed using the omega advancement flap between 2010 and 2014. In this technique, a circular-shaped flap that has an equal diameter with the defect is planned adjacent to the defect. To facilitate the advancement of the flap and to avoid standing cones, deepithelialized equilateral triangular flaps are designed on both sides of the main circular flap. The circular flap is easily moved to the defect by pulling of the triangular flaps with minimal tension.

Results: All flaps survived without complication such as infection, hematoma or flap necrosis. No secondary surgery was required to correct contour deformities such as standing cones and trap-door deformities. The results were satisfactory aesthetically and functionally.

Conclusions: The omega advancement flap is an easy and reliable procedure for reconstruction of circular skin defects located on various anatomical regions.

Level Of Evidence Iv: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00266-016-0751-5DOI Listing

Publication Analysis

Top Keywords

advancement flap
20
omega advancement
12
flap
12
circular flap
12
skin defects
12
flap circular
8
circular skin
8
standing cones
8
triangular flaps
8
circular
6

Similar Publications

Deep cutaneous wounds, which are difficult to heal and specifically occur on dynamic body surfaces, remain a substantial healthcare challenge in clinical practice because of multiple underlying factors, including excessive reactive oxygen species, potential bacterial infection, and extensive degradation of the extracellular matrix (ECM) which further leads to the progressive deterioration of the wound microenvironment. Any available individual wound therapy, such as antibiotic-loaded cotton gauze, cannot address all these issues. Engineering an advanced multifunctional wound dressing is the current need to promote the overall healing process of such wounds.

View Article and Find Full Text PDF

Donor site morbidity remains a significant concern in free flap microsurgery, with implications that extend beyond immediate postoperative outcomes to affect patients' long-term quality of life. This review explores the multi-faceted impact of donor site morbidity on physical, psychological, social, and occupational well-being, synthesizing findings from the existing literature. Particular attention is given to the functional limitations, sensory deficits, aesthetic outcomes, and chronic pain associated with commonly utilized free flaps.

View Article and Find Full Text PDF

The toxicokinetics of nitrosamines remain a mystery to this day, though it appears that the role of nitrosamines in potentiating the generation of mutations required for the onset of skin cancer continues to be a significant concern. Nitrosamines are mutagens, genotoxic substances, and mediators of phototoxicity/carcinogenicity, whose long-term daily usage, in the context of polypharmacy, can result in the parallel appearance of heterogeneous forms of skin cancer: keratinocytic and melanocytic. But a number of clinical observations suggest that it is the nitrosamines that potentiate the multiple occurrences of skin cancer over the years, or recurrences of skin cancer localized in areas exposed to solar radiation.

View Article and Find Full Text PDF

For managing peri-implantitis, a variety of treatment modalities involving both surgical and nonsurgical methods including implantoplasty have been proposed. Implants that are placed in a free fibula flap are more prone to peri-implantitis due to the absence of firm, keratinized mucosa. Prosthetic design that offers adequate hygiene access should be designed whenever possible; otherwise, it may lead to the accumulation of plaque or biofilm that may lead to peri-implant diseases.

View Article and Find Full Text PDF

Recent Advancements in Robotic-assisted Plastic Surgery Procedures: A Systematic Review.

Plast Reconstr Surg Glob Open

January 2025

Department of Plastic and Reconstructive Surgery, Royal Free NHS Foundation Trust, London, United Kingdom.

Background: There has been a delayed, yet steady uptake of robotic-assisted surgery over the past decade within the field of plastic surgery. In an era of rapidly evolving scientific and technological development, there is a need for an update on the current literature for robotic-assisted plastic surgery procedures.

Methods: Searches were conducted across major databases, including MEDLINE, Embase, and Central for published literature from March 2023 to December 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!