There are limited contemporary studies comparing coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) for isolated proximal left anterior descending (LAD) disease. Increasing stent length and decreasing stent diameters are associated with increased risk of restenosis and adverse outcomes after PCI. Whether these parameters influence outcomes when comparing CABG and PCI is unclear. We compared CABG and PCI in 3,473 patients who underwent revascularization for isolated proximal LAD disease from 2004 to 2015 at Harefield Hospital, UK; 3,078 patients (89%) had PCI and 384 patients had CABG (11%). We analyzed all-cause mortality at 3 years. The unadjusted mortality rates were similar (PCI vs CABG: 9.5% vs 7.0%, p = 0.109). PCI was associated with comparable mortality (hazard ratio [HR] 1.15, 95% confidence interval [CI] 0.70 to 1.89, p = 0.593), even when stratified to bare-metal stents (HR 1.58, 95% CI 0.89 to 2.80, p = 0.121); first-generation drug-eluting stents (FDES; HR 1.16, 95% CI 0.67 to 2.02, p = 0.597); and second-generation DES (SDES; HR 0.98, 95% CI 0.53 to 1.82, p = 0.946). Stent diameters did not influence outcomes, but PCI was associated with higher mortality when stent length ≥30 mm (HR 2.12, 95% CI 1.12 to 4.03, p = 0.022). There was a linear association between stent length and mortality, and for every 1-mm increase in stent length, the 3-year mortality increased by 0.32%. In conclusion, for patients with isolated proximal LAD disease, PCI and CABG were associated with similar mortality. Increasing stent length was progressively associated with worse outcomes with PCI. For longer segments of disease requiring stent lengths ≥30 mm, CABG may be associated with better outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2016.11.031DOI Listing

Publication Analysis

Top Keywords

stent length
20
isolated proximal
16
lad disease
12
outcomes pci
12
pci
10
coronary artery
8
artery bypass
8
bypass grafting
8
percutaneous coronary
8
coronary intervention
8

Similar Publications

: This study aimed to evaluate whether gender-related anatomical differences in proximal aortic neck morphology affect the feasibility and outcomes of endovascular aortic aneurysm repair (EVAR) in women with abdominal aortic aneurysms (AAA). : This study performed a retrospective analysis of patients electively treated by EVAR for infrarenal AAA between January 2019 and December 2023. Demographics, anatomical characteristics, and stent graft details were analyzed.

View Article and Find Full Text PDF

Background And Aim: Stent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.

Methods: Three minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models.

View Article and Find Full Text PDF

In this research, we explored the relationship between the AIP and clinical outcomes in patients undergoing PCI. A total of 2533 consecutive patients who underwent PCI were included in this retrospective cohort study, and the data from 2098 patients were used. AIP is calculated based on the log (triglycerides/high-density lipoprotein-cholesterol).

View Article and Find Full Text PDF

Objectives: Prediction of in-stent restenosis (ISR) is clinically important for patients with peripheral artery disease in their superficial femoral arteries (SFA) who have been treated with stenting. The aim of this study was to construct and validate a predictive model for ISR after SFA stenting based on a series of clinical and ultrasonic parameters.

Methods: This retrospective study included 381 patients who were treated with self-expanding bare nitinol stents in their SFA at our hospital between January 1, 2018, and January 1, 2022.

View Article and Find Full Text PDF

Purpose: To report a case series on using a novel semi-branch feature in custom-made stent-grafts in the endovascular treatment of complex aortic aneurysms and summarize the contemporary usage of this technology.

Case Series: Four patients underwent endovascular aortic aneurysm repair (EVAR) with a custom-made semi-branch stent-graft (Semi-Branch Endovascular Aortic Aneurysm Repair [SBEVAR]). Two male patients, 75- and 76-year-old, were treated due to failed EVAR with late-type Ia endoleak, and the other two, 80- and 55-year-old male patients, due to a juxta-renal aortic abdominal aneurysm (JRAAA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!