Dynamic systolic compression of the coronary arteries is almost always due to the existence of myocardial bridging that is most commonly localized in the middle segment of the left anterior descending coronary artery. However, it has rarely been reported in patients with pericardial adhesions, tumor, foreign body, or pseudoaneurysms. Only rare case reports exist regarding dynamic coronary compression by a dyskinetic left ventricular aneurysm. We present a patient with a myocardial bridge-like systolic compression of the distal left anterior descending caused by postinfarction dyskinetic left ventricular aneurysm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5186298PMC
http://dx.doi.org/10.1055/s-0034-1396790DOI Listing

Publication Analysis

Top Keywords

systolic compression
12
left anterior
12
anterior descending
12
dyskinetic left
12
left ventricular
12
ventricular aneurysm
12
dynamic systolic
8
descending coronary
8
coronary artery
8
postinfarction dyskinetic
8

Similar Publications

Controlling the stability of monodisperse phospholipid-coated microbubbles by tuning their buckling pressure.

J Colloid Interface Sci

January 2025

BIOS/Lab on a Chip Group, Max Planck Center Twente for Complex Fluid Dynamics, MESA+ Institute for Nanotechnology, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, P.O. Box 217, Enschede, 7500 AE, the Netherlands. Electronic address:

Hypothesis: Monodisperse phospholipid-coated microbubbles, with a size and resonance frequency tuned to the ultrasound driving frequency, have strong potential to enhance sensitivity, efficiency, and control in emerging diagnostic and therapeutic applications involving bubbles and ultrasound. A key requirement is that they retain their gas volume and shell material during physiologic pressure changes and withstand the overpressure during intravenous injection. The shell typically comprises a mixture of a phospholipid (e.

View Article and Find Full Text PDF

Posterior reversible encephalopathy syndrome (PRES) is a clinical manifestation of various underlying causes, characterized by the combination of clinical and imaging findings associated with the posterior cerebral areas and relating to arterial hypertension and endothelial dysfunction. No association was made so far between PRES and McCune-Albright syndrome (MAS), a rare genetic disorder resulting in fibrous dysplasia. A 33-year-old female with MAS was presented to the emergency department of the 417 Army Share Fund Hospital in Athens (Greece) after seizure activity with two episodes of ocular upward deviation and transient facial palsy, each lasting a few minutes, followed by a postictal phase.

View Article and Find Full Text PDF

Background: Pulmonary hypertension caused by extrinsic pulmonary vascular compression secondary to mediastinal neuroendocrine tumours is a very rare condition, posing a diagnostic challenge. There is no clear consensus regarding the best treatment strategy due to the lack of clinical data, leading to poor prognoses for these patients.

Case Summary: We present the case of a 38-year-old man hospitalized with signs of pulmonary hypertension and acute heart failure.

View Article and Find Full Text PDF

A young man presented with complaints of angina on exertion and dyspnoea on exertion for the last 3 months. On evaluation, he was found to have a cystic mass in the left ventricle with severe left ventricular systolic dysfunction. A cardiac MRI revealed a multiloculated mass in the left ventricle with multiple septa with internal enhancement and CT coronary angiography revealed compression of a coronary artery by the cystic mass.

View Article and Find Full Text PDF

Image reconstruction impacts haemodynamic parameters derived from 4D flow magnetic resonance imaging with compressed sensing.

Eur Heart J Imaging Methods Pract

October 2024

Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden.

Aims: 4D blood flow measurements by cardiac magnetic resonance imaging (CMR) can be used to simplify blood flow assessment. Compressed sensing (CS) can provide better flow measurements than conventional parallel imaging (PI), but clinical validation is needed. This study aimed to validate stroke volume (SV) measurements by 4D-CS in healthy volunteers and patients while also investigating the influence of the CS image reconstruction parameter on haemodynamic parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!