Intracochlear Pressure Changes due to 2 Electrode Types: An Artificial Model Experiment.

Otolaryngol Head Neck Surg

1 Department of Otolaryngology-Head and Neck Surgery, Unfallkranken-haus Berlin, Berlin, Germany.

Published: April 2017

Objective To preserve residual hearing in cochlear implant surgery, the electrode design has been refined, and an atraumatic insertion has become one aspect of cochlear implant research. Previous studies have described the effect of insertion speed and opening of the round window membrane on intracochlear pressure changes. The aim of our current study was to observe intracochlear pressure changes due to different cochlear implant electrodes in an artificial cochlear model with stable surrounding factors. Study Design Prospective controlled study. Setting Tertiary referral center. Subjects and Methods The experiments were performed in an artificial cochlear model with a pressure sensor in the apical area. With straight and perimodiolar electrode arrays, 5 insertions with the same insertion speed and 5 insertions over the same time were performed. Results With the perimodiolar high-volume electrode, significantly greater intracochlear fluid pressure changes were observed than with the straight electrode. Compared with the straight electrode, the perimodiolar electrode induces significantly higher pressure peaks (1.12 ± 0.15 vs 0.86 ± 0.05 mm Hg, P = .006) and significantly higher amplitudes (0.38 ± 0.07 vs 0.09 ± 0.07 mm Hg, P < .001). Conclusion The reliable preservation of residual hearing is an important multifactorial challenge in modern cochlear implant surgery. Insertion speed, handling, and electrode design are known to influence the preservation of residual hearing. In our artificial model experiments, we could prove objectively that the volume of the electrodes has a significant influence on the intracochlear pressure changes during cochlear implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0194599816684104DOI Listing

Publication Analysis

Top Keywords

pressure changes
20
intracochlear pressure
16
cochlear implant
16
residual hearing
12
insertion speed
12
electrode
8
artificial model
8
implant surgery
8
electrode design
8
changes cochlear
8

Similar Publications

Background: High blood pressure (BP) is linked to unhealthy lifestyles, and its treatment includes medications and exercise therapy. Many previous studies have evaluated the effects of exercise on BP improvement; however, exercise requires securing a location, time, and staff, which can be challenging in clinical settings. The antihypertensive effects of dance exercise for patients with hypertension have already been verified, and it has been found that adherence and dropout rates are better compared to other forms of exercise.

View Article and Find Full Text PDF

Purpose: Eccentric calf training for Achilles tendinopathy shows variable success in athletes. Recent insights suggest a role for tendon fluid flow (exudation or redistribution) during exercise, which explains post-exercise reductions in thickness and increases in stiffness of the tendon. This fluid flow is thought to be beneficial as it may promote tendon remodeling, reduce intratendinous pressure, and alleviate pain.

View Article and Find Full Text PDF

Purpose: Sleep deprivation and elevated blood pressure (BP) increase the risk of cardiovascular diseases. However, the effects of sleep deprivation on BP response, especially at exercise onset remain unclear. We aimed to elucidate the effects of experimental sleep deprivation (ESD) on resting and exercise BPs, including that at exercise onset, and investigate whether a night-time nap during ESD changes the ESD-altered BP.

View Article and Find Full Text PDF

Background: The acute effects of high-intensity interval training (HIIT) on blood pressure (BP) may depend on the exercise protocol performed. Purpose: To compare the acute effect of high and low-volume HIIT on post-exercise and ambulatory BP in untrained older females diagnosed with both type 2 diabetes (T2D) and hypertension (HTN). Methods: Fifteen females (69 [65 ─ 74] years) completed a crossover study with three experimental conditions: 1) REST (35 min in sitting position); 2) HIIT10 (10 × 1 min at 90% heart rate max [HRmax]), and 3) HIIT4 (4 × 4 min at 90% HRmax).

View Article and Find Full Text PDF

Pinto Bean Pressure Wraps: A Novel Approach to Treating Digital Warts.

Cutis

November 2024

Forefront Dermatology, West Burlington, Iowa.

Identifying an optimal treatment method for verruca vulgaris can be a frustrating challenge for clinicians. We describe the use of a pinto bean pressure wrap to induce ischemic change in digital warts. This novel technique provides a low-cost, low-risk, and nearly pain-free home-based treatment option with response rates similar to those of other commonly employed methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!