Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes -0.1 ml; CI -31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5359215PMC
http://dx.doi.org/10.1007/s10278-016-9936-3DOI Listing

Publication Analysis

Top Keywords

semi-automated segmentation
16
segmentation tool
12
volumetric analysis
12
analysis kidney
12
tool modified
8
modified ellipsoid
8
ellipsoid formula
8
formula volumetric
8
kidney non-contrast
8
non-contrast t2-weighted
8

Similar Publications

A novel clinical investigation using deep learning and human-in-the-loop approach in orbital volume measurement.

J Craniomaxillofac Surg

January 2025

Department of Plastic and Reconstructive Surgery, School of Medicine, Kyungpook National University, Daegu, Republic of Korea. Electronic address:

Orbital volume assessment is crucial for surgical planning. Traditional methods lack efficiency and accuracy. Recent studies explore AI-driven techniques, but research on their clinical effectiveness is limited.

View Article and Find Full Text PDF

Objective: GM1 gangliosidosis is a rare lysosomal storage disorder characterized by the accumulation of GM1 gangliosides in neuronal cells, resulting in severe neurodegeneration. Currently, limited data exists on the brain volumetric changes associated with this disease. This study focuses on the late-infantile and juvenile subtypes of type II GM1 gangliosidosis, aiming to quantify brain volumetric characteristics to track disease progression.

View Article and Find Full Text PDF

Aim: Evaluation of pericoronary adipose tissue changes induced by inflammation by non-invasive techniques is challenging.

Purpose: To find the association between pericoronary adipose tissue attenuation (FAI) changes and future acute coronary events in nonobstructive coronary artery disease.

Materials And Methods: Ours was a single-centre, prospective observational study on patients with atypical chest pain who underwent coronary computed tomography angiography (CCTA).

View Article and Find Full Text PDF

: Chronic low back pain (CLBP) is prevalent among older adults and leads to significant functional limitations and reduced quality of life. Segmental stabilization exercises (SSEs) are commonly used to treat CLBP, but the selective activation of deep abdominal muscles during these exercises can be challenging for patients. To support muscle activation, physiotherapists use biofeedback methods such as palpation and ultrasound imaging.

View Article and Find Full Text PDF

Imaging the entire cardiomyocyte network in entire small animal hearts at single cell resolution is a formidable challenge. Optical microscopy provides sufficient contrast and resolution in 2d, however fails to deliver non-destructive 3d reconstructions with isotropic resolution. It requires several invasive preparation steps, which introduce structural artefacts, namely dehydration, physical slicing and staining, or for the case of light sheet microscopy also clearing of the tissue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!