To investigate skin, subepidermal low echogenic band (SELEB), and subcutaneous tissue (SCT) thickness as well as the degree of increase in subcutaneous echogenicity (SEG) and subcutaneous echo-free space (SEFS) in arms with lymphedema (LE). The skin and SCT of both arms of 30 patients with unilateral stage II breast cancer-related LE were scanned at five points (medial/lateral upper arm/forearm and dorsum of the hand). SEG and SEFS grades were determined according to severity (range: 0-2). All measured parameters, except the SEFS in the medial upper arm, were significantly higher on the LE side than on the normal (N) side. The parameters differed most remarkably in the medial forearm (MFA; skin: LE 1.7 ± 0.8 mm vs. N 0.8 ± 0.2 mm; SELEB: LE 1.0 ± 0.6 mm vs. N 0.3 ± 0.1 mm; SCT: LE 8.7 ± 3.4 mm vs. N 3.8 ± 2.0 mm; SEG: LE 0.9 ± 0.5 vs. N 0.1 ± 0.3; and SEFS: LE 0.5 ± 0.7 vs. N 0). The differences in the thickness of the skin, SELEB, and SCT and the SEG and SEFS grades between the LE and N arms seemed most evident in the MFA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5174992PMC
http://dx.doi.org/10.3400/avd.oa.16-00086DOI Listing

Publication Analysis

Top Keywords

seg sefs
12
subcutaneous tissue
8
breast cancer-related
8
sefs grades
8
skin seleb
8
seleb sct
8
sct seg
8
skin
5
sefs
5
skin subcutaneous
4

Similar Publications

Subcutaneous echogenicity grade (SEG) and subcutaneous echo-free space (SEFS) grade allow semiquantitation of nonspecific subcutaneous tissue inflammation and fluid accumulation in breast cancer-related lymphedema. However, inter- and intrarater reliability of SEG and SEFS is yet to be reported. The objective of this study is to assess inter-rater and intrarater reliability of SEG and SEFS in patients with breast cancer-related lymphedema.

View Article and Find Full Text PDF

To investigate skin, subepidermal low echogenic band (SELEB), and subcutaneous tissue (SCT) thickness as well as the degree of increase in subcutaneous echogenicity (SEG) and subcutaneous echo-free space (SEFS) in arms with lymphedema (LE). The skin and SCT of both arms of 30 patients with unilateral stage II breast cancer-related LE were scanned at five points (medial/lateral upper arm/forearm and dorsum of the hand). SEG and SEFS grades were determined according to severity (range: 0-2).

View Article and Find Full Text PDF

Objective: To use subcutaneous ultrasonography to differentiate legs with edema because of obesity-related functional venous insufficiency (FVI), immobility-related FVI (FVI), secondary lymphedema (LE), LE complicated by obesity (LE), and LE complicated by immobility (LE).

Methods: Ninety-nine legs with edema (16 FVI, 32 FVI, 22 LE, 9 LE, and 20 LE), and 10 normal legs were examined. Subcutaneous tissue ultrasonography was performed at eight points (medial, lateral, upper, lower, thigh, and calf) in each leg.

View Article and Find Full Text PDF

Objective: The purpose of this study was to discuss the mode of increase in leg volume during complex physical therapy (CPT) for lymphedema using subcutaneous tissue ultrasonography.

Methods: Thirty-eight patients (51 legs) with secondary lymphedema who were treated by CPT for longer than 2 years (3.0 ± 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!