This study aims to determine to what extent the task for an action system in its initial development relies on functional and anatomical components. Fifty-two able-bodied participants were randomly assigned to one of three experimental groups or to a control group. As a pre- and post-test all groups performed a computer game with the same goal and using the same musculature. One experimental group also trained to perform this test, while the other two experimental groups learned to perform a game that differed either in its goal or in the musculature used. The observed change in accuracy indicated that retaining the goal of the task or the musculature used equally increased transfer performance relative to controls. Conversely, changing either the goal or the musculature equally decreased transfer relative to training the test. These results suggest that in the initial development of an action system, the task to which the system pertains is not specified solely by either the goal of the task or the anatomical structures involved. It is suggested that functional specificity and anatomical dependence might equally be outcomes of continuously differentiating activity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5156961PMC
http://dx.doi.org/10.3389/fpsyg.2016.01945DOI Listing

Publication Analysis

Top Keywords

goal musculature
12
action system
8
initial development
8
experimental groups
8
goal task
8
musculature equally
8
task
5
goal
5
anatomy action
4
action systems
4

Similar Publications

Learning curve and long-term outcomes of minimally invasive correction and fusion for adolescent idiopathic scoliosis.

Spine Deform

November 2024

Dell Medical School, The University of Texas, Ascension Texas Spine and Scoliosis, 1004 West 32nd Street, Suite 200, Austin, TX, 78705, USA.

Study Design: Retrospective analysis.

Objective: This study sought to report the long-term outcomes of patients that underwent minimally invasive surgery (MIS) correction for Adolescent Idiopathic Scoliosis (AIS) in terms of radiographic, clinical, and patient-reported outcomes. Furthermore, we examined the learning curve of MIS technique over the course of 13 years.

View Article and Find Full Text PDF

Background And Objective: To objectively analyze the effect of three-dimensional screen-based surgery (3D SBS) versus traditional operating microscope (TOM) on operating surgeon posterior chain postural musculature during ophthalmic surgery. We hypothesized an increase in median amplitude of electromyography (EMG) signals when using a TOM compared to 3D SBS. The goal was to assess surgical ergonomics that may contribute to cervical and lumbar spine pathology.

View Article and Find Full Text PDF

Hanney, WJ, Perez, A, Collado, G, Palmer, AC, Wilson, AT, Richardson, RM, and Kolber, MJ. J Strength Cond Res 38(11): 1854-1859, 2024-Kettlebell swings (KBSs) are commonly used to target the lumbar erector spinae and lower body musculature. This exercise exhibits distinct loading properties that requires cyclical contraction of the trunk extensors and posterior chain, potentially explaining its novel influence on muscle contractility.

View Article and Find Full Text PDF

Muscle-Driven Predictive Physics Simulations of Quadrupedal Locomotion in the Horse.

Integr Comp Biol

September 2024

Department of Musculoskeletal & Ageing Science, Institute of Life Course & Medical Sciences, University of Liverpool, The William Henry Duncan Building, 6 West Derby Street, Liverpool L7 8TX, UK.

Musculoskeletal simulations can provide insights into the underlying mechanisms that govern animal locomotion. In this study, we describe the development of a new musculoskeletal model of the horse, and to our knowledge present the first fully muscle-driven, predictive simulations of equine locomotion. Our goal was to simulate a model that captures only the gross musculoskeletal structure of a horse, without specialized morphological features.

View Article and Find Full Text PDF

Metallic Lateralized-Offset Glenoid Reverse Shoulder Arthroplasty.

JBJS Essent Surg Tech

July 2024

Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland.

Background: Metallic lateralized-offset glenoid reverse shoulder arthroplasty (RSA) for cuff tear arthropathy combines the use of a metallic augmented baseplate with a metaphyseally oriented short stem design that can be applied at a 135° or 145° neck-shaft angle, leading to additional lateralization on the humeral side. Lateralization of the center of rotation decreases the risk of inferior scapular notching and improves external rotation, deltoid wrapping, residual rotator cuff tensioning, and prosthetic stability. Metallic increased-offset RSA (MIO-RSA) achieves lateralization and corrects inclination and retroversion while avoiding graft resorption and other complications of bony increased-offset RSA (BIO-RSA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!