Effect of Unmodulated 5-kHz Alternating Currents Versus Transcutaneous Electrical Nerve Stimulation on Mechanical and Thermal Pain, Tactile Threshold, and Peripheral Nerve Conduction: A Double-Blind, Placebo-Controlled Crossover Trial.

Arch Phys Med Rehabil

Sensorimotor Function Group, Hospital Nacional de Parapléjicos, Toledo, Spain; Stoke Mandeville Spinal Research, National Spinal Injuries Centre, Aylesbury, United Kingdom; Harris Manchester College, University of Oxford, Oxford, United Kingdom.

Published: May 2017

AI Article Synopsis

Article Abstract

Objective: To investigate the effect of unmodulated 5-kHz alternating current on mechanical pain threshold (MPT), heat pain threshold (HPT), tactile threshold (TT), and peripheral nerve conduction (PNC) compared with transcutaneous electrical nerve stimulation (TENS) and sham stimulation.

Setting: National referral center.

Design: Randomized, double-blind, placebo-controlled crossover trial.

Participants: Healthy volunteers (N=38). No dropouts or adverse events were reported.

Intervention: TENS, unmodulated 5-kHz currents, and sham stimulation were applied on the radial nerve for 20 minutes with a 24-hour washout period between them and concealed intervention allocation.

Main Outcome Measures: Four measures were taken: before, during, and 2 after the interventions. Algometry was used to assess MPT, a Peltier thermode for HPT using the method of limits, Von Frey filaments for TT, and radial nerve compound action potential.

Results: No differences were observed on MPT, HPT, and PNC when 5-kHz current and TENS were compared. However, TT increased 56.2mN (95% confidence interval [CI], 28.8-83.6) in the TENS group compared with the 5-kHz current group during intervention. Compared with sham stimulation during intervention, MPT increased 4.7N (95% CI, 0.3-9.2) using 5-kHz current and 10.4N (95% CI, 3.5-17.3) with TENS. TT increased 17.2mN (95% CI, 4.7-29.7) with 5-kHz current and 73.4mN (95% CI, 47.5-99.2) with TENS. However, HPT increased 1.0°C (95% CI, 0.2-2.0) only with TENS. For the PNC, no differences were found among the 3 groups.

Conclusions: Unmodulated 5-kHz current produced an increase in somatosensory thresholds that was greater than placebo but not when compared with TENS; however, participants perceived 5-kHz currents to be more comfortable and showed more habituation to them.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apmr.2016.11.020DOI Listing

Publication Analysis

Top Keywords

5-khz current
20
unmodulated 5-khz
16
5-khz alternating
8
transcutaneous electrical
8
electrical nerve
8
nerve stimulation
8
tactile threshold
8
threshold peripheral
8
peripheral nerve
8
nerve conduction
8

Similar Publications

This paper is devoted to the development of a window-type inductive current transformer (iCT) with a rated primary current equal to 400 A and two secondary windings with rated currents of 5 A and 1 A. Its novelty concerns the presentation of this process in the case of an iCT with a 0.2S accuracy class ensured not only for a sinusoidal current of a frequency of 50 Hz but also for the transformation of distorted current in the harmonic frequency range from 50 Hz to 5 kHz.

View Article and Find Full Text PDF

Oral cancer (OC) is a disease with poor prognosis mainly due to late diagnosis. There is considerable interest in the use and development of rapid, point of care (POC) non-invasive methods that can accelerate the diagnostic process. Bioimpedance (BI) is resistance to the passage of electric currents through tissue that reflects structural changes in the tissue.

View Article and Find Full Text PDF

Single Laboratory Evaluation of the Q20+ Nanopore Sequencing Kit for Bacterial Outbreak Investigations.

Int J Mol Sci

November 2024

Genomics Development and Applications Branch, Division of Food Safety Genomics, Office of Applied Microbiology and Technology, Office of Laboratory Operations and Applied Science, Human Foods Program, Food & Drug Administration, College Park, MD 20740, USA.

Article Synopsis
  • * This study tested the effectiveness of Oxford Nanopore Technologies (ONT) for rapid and cost-efficient identification of foodborne pathogens, comparing various DNA extraction and sequencing methods.
  • * Results showed that ONT could accurately identify pathogens and their characteristics, but some variations in genome assembly were noted, indicating the need for further refinement of the process.
View Article and Find Full Text PDF
Article Synopsis
  • Frequency importance functions help measure how different sound frequencies affect our ability to recognize speech, especially in noisy environments.
  • This study looks at how frequency importance changes when listening to speech amidst background noise versus competing voices, as well as when those voices are positioned differently in space.
  • Findings reveal that the significance of specific frequencies varies with the type of background noise and whether the sound sources are separated, highlighting that higher frequencies are generally less crucial when multiple talkers are present.
View Article and Find Full Text PDF
Article Synopsis
  • - KFACs (Kilohertz-frequency alternating currents) help reduce muscle atrophy and weakness, but the best stimulation settings are still unclear.
  • - The study tested two types of KFACs (Aussie at 1 kHz and Russian at 2.5 kHz) on healthy participants to evaluate their effects on muscle torque and discomfort.
  • - Results showed that Aussie currents were more effective for muscle performance, especially at higher efforts, but caused greater discomfort, while a 20% duty cycle improved efficiency in submaximal efforts.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!