Drug-eluting stents (DES) have been shown to significantly reduce clinical and angiographic restenosis compared to bare metal stents (BMS). The polymer coatings on DES elute antiproliferative drugs to inhibit intimal proliferation and prevent restenosis after stent implantation. Permanent polymers which do not degrade in vivo may increase the likelihood of stent-related delayed arterial healing or polymer hypersensitivity. In turn, these limitations may contribute to an increased risk of late clinical events. Intuitively, a polymer which degrades after completion of drug release, leaving an inert metal scaffold in place, may improve arterial healing by removing a chronic source of inflammation, neoatherosclerosis, and/or late thrombosis. In this way, a biodegradable polymer may reduce late ischemic events. Additionally, improved healing after stent implantation could reduce the requirement for long-term dual antiplatelet therapy and the associated risk of bleeding and cost. This review will focus on bioabsorbable polymer-coated DES currently being evaluated in clinical trials.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5452149 | PMC |
http://dx.doi.org/10.2174/1573403X12666161222155230 | DOI Listing |
Trials
October 2024
Department of Internal Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea.
Catheter Cardiovasc Interv
February 2022
Boston Scientific Corporation, Marlborough, Massachusetts, USA.
Objectives: The EVOLVE 48 study evaluated the safety and effectiveness of the SYNERGY 48 mm stent for the treatment of long lesions.
Background: Clinical evidence supporting the use of very long stents during percutaneous coronary intervention (PCI) is limited. The bioabsorbable polymer SYNERGY stent has shown good long-term data in a broad population of patients undergoing PCI.
Cardiovasc Revasc Med
February 2022
CVPath Institute, Inc., 19 Firstfield Road, Gaithersburg, MD 20878, United States of America. Electronic address:
Background: Cytokine storm-related hypercoagulation may be important in the pathogenesis of stent thrombosis in patients with SARS-CoV-2. Whether stent polymers behave differently under such conditions has never been explored.
Methods: Fluorinated polymer-nanocoated and uncoated COBRA stents (CeloNova), BioLinx-polymer-coated Resolute Onyx stents (Medtronic), and Synergy stents (Boston Scientific), which are abluminally coated with a bioabsorbable polymer, were exposed to human blood from healthy donors which was supplemented with 400 pg/mL IL-6 and 100 pg/mL TNF-α, similar to what is seen in cytokine storm caused by SARS-CoV-2.
Circ Rep
December 2020
Boston Scientific Corporation Marlborough, MA USA.
SYNERGY is a thin-strut, platinum-chromium metal alloy stent with an ultrathin abluminal everolimus-eluting bioabsorbable polymer. EVOLVE II was a global randomized controlled trial that enrolled 1,684 patients treated with either a SYNERGY or durable polymer PROMUS Element Plus (PE+) everolimus-eluting stent, including 155 patients from Japanese sites. This substudy analyzed 5-year clinical outcomes in the Japanese and non-Japanese cohorts.
View Article and Find Full Text PDFCirc Cardiovasc Interv
March 2021
Lindner Center for Research and Education at Christ Hospital, Cincinnati, OH (D.J.K.).
[Figure: see text].
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!