In the staging process of the breast cancer, demonstrating metastasis of the sentinel lymph node (SLN) has an important prognostic value, in both humans and animals. The aim of this prospective case-control study was to determine the diagnostic value of computed tomographic indirect lymphography (CT-LG) for detecting SLN metastasis in dogs with mammary cancer. Thirty-three female dogs with tumors in the abdominal and inguinal mammary glands were prospectively selected and subjected to CT-LG, 1 and 5 min after injection of 1 ml of contrast agent (iopamidol) in the subareolar tissue of the neoplastic and the contralateral normal mammary glands. The pattern of postcontrast opacification, degree of postcontrast enhancement, and size and shape were assessed in 65 SLNs in total and were correlated with histopathological findings. The absence of opacification or heterogeneous opacification 1 min after contrast medium injection showed the highest sensitivity, specificity, and accuracy (93%, 100%, and 98.4%, respectively). In images taken 1 min after injection, an absolute density value lower than 444 Hounsfield units (HU) in the center of the SLN also provided significant sensitivity and specificity (93.8% and 75%, respectively). The size and shape of the SLN (maximum and minimum diameter, maximum/minimum diameter ratio, maximum diameter/height of fifth thoracic vertebral body ratio) showed the lowest sensitivity and specificity. Results of this study support the hypothesis that CT-LG could help in the assessment of SLN metastasis in cases of mammary gland tumors in dogs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vru.12460DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
12
sentinel lymph
8
lymph node
8
mammary gland
8
gland tumors
8
computed tomographic
8
tomographic indirect
8
indirect lymphography
8
sln metastasis
8
mammary glands
8

Similar Publications

Background: Computed tomography (CT)-derived low muscle mass is associated with adverse outcomes in critically ill patients. Muscle ultrasound is a promising strategy for quantitating muscle mass. We evaluated the association between baseline ultrasound rectus femoris cross-sectional area (RF-CSA) and intensive care unit (ICU) mortality.

View Article and Find Full Text PDF

A fluorescent aptasensor was developed based on target-induced hairpin conformation switch coupled with nicking enzyme-assisted signal amplification (NESA) to detect the oligomeric form of ß-amyolid peptide (AβO) in cerebrospinal fluid. The hairpin DNA probe (HP) was specifically designed to recognize AβO. When AβO is present in the sensing system, it induces an HP conformational switch and triggers the NESA reaction.

View Article and Find Full Text PDF

An innovative colorimetric sensing strategy was developed for the detection of glucose by the integration of glucose aptamer, glucose oxidase (GOx), and horseradish peroxidase (HRP), termed aptamer proximal enzyme cascade reactions (APECR). In the presence of glucose, aptamer binding enables GOx to catalyze glucose oxidation into HO efficiently. Subsequently, the adjacent HRP catalyzes the oxidation of the peroxidase substrate, 2,2'-biazobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), utilizing the generated HO, resulting in a distinct color change.

View Article and Find Full Text PDF

Enhancing safety in CT-guided lung biopsies: correlation of MinIP imaging with pneumothorax risk prediction.

Insights Imaging

January 2025

Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Objectives: This study aimed to evaluate whether minimum-intensity projection (MinIP) images could predict complications in CT-guided lung biopsies.

Methods: We retrospectively analyzed 72 procedures from January 2019 to December 2023, categorizing patients by pneumothorax and the severity of hemorrhage (grade 2 or higher). Radiodensity measurements were performed using lung window (LW) and MinIP (10-mm slab) images.

View Article and Find Full Text PDF

Coronary artery calcification (CAC) is a key marker of coronary artery disease (CAD) but is often underreported in cancer patients undergoing non-gated CT or PET/CT scans. Traditional CAC assessment requires gated CT scans, leading to increased radiation exposure and the need for specialized personnel. This study aims to develop an artificial intelligence (AI) method to automatically detect CAC from non-gated, freely-breathing, low-dose CT images obtained from positron emission tomography/computed tomography scans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!