A disposable microfluidic amperometric dual-sensor was developed for the detection of glycated hemoglobin (HbA) and total hemoglobin (Hb), separately, in a finger prick blood sample. The accurate level of total Hb was determined through the measurements of the cathodic currents of total Hb catalyzed by a toluidine blue O (TBO)-modified working electrode. Subsequently, after washing unbound Hb in the fluidic channel of dual sensor with PBS, the cathodic current by only HbA captured on aptamer was monitored using another aptamer/TBO-modified working electrode in the channel. To modify the sensor probe, poly(2,2´:5´,5″-terthiophene-3´-p-benzoic acid) and a multi-wall carbon nanotube (MWCNT) composite layer (pTBA@MWCNT) was electropolymerized on a screen printed carbon electrode (SPCE), followed by immobilization of TBO for the total Hb probe and aptamer/TBO for the HbA probe, respectively. The characterization of each sensor surface was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), field-emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). The experimental conditions affecting the analytical signal were optimized in terms of the amount of TBO, pH, temperature, binding time, applied potential, and the content ratio of monomer and MWCNT. The dynamic ranges of Hb and HbA were from 0.1 to 10µM and from 0.006 to 0.74µM, with detection limits of 82(±4.2)nM and 3.7(±0.8)nM, respectively. The reliability of the proposed microfluidic dual-sensor for a finger prick blood sample (1µL) was evaluated in parallel with a conventional method (HPLC) for point-of-care analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2016.12.038 | DOI Listing |
Indian J Crit Care Med
January 2025
Department of Medicine, All India Institute of Medical Sciences (AIIMS), New Delhi, India.
Background: Glycemic variability (GV) is the third domain of sepsis-induced dysglycemia, after hyperglycemia and hypoglycemia, potentially leading to adverse outcomes. This study analyzed the association of GV with in-hospital mortality and length of stay (LOS) in non-diabetic sepsis patients.
Materials And Methods: In this prospective observational study, non-diabetic sepsis patients were followed till day 14 of hospital stay, and blood glucose levels were assessed by finger-prick method (seven times per day) daily; clinico-laboratory and GV parameters [standard deviation (SD), coefficient of variation (CV), mean amplitude of glycemic excursion (MAGE)] were assessed on days 1, 3, 5, 7, 10, and 14 of admission.
Malar J
January 2025
Swiss Tropical and Public Health Institute, Allschwil, Switzerland.
Background: The Highlands of Papua New Guinea are non-endemic for malaria compared to the rest of the country. This study aimed to explore the local transmission of malaria in the Highlands through a cross-sectional school survey coupled with reactive case detection.
Methods: Between July and November 2019, 5575 schoolchildren and 1048 household members were screened for malaria using Rapid Diagnostic Tests, subsequently validated by light microscopy.
J Gen Fam Med
January 2025
Department of Pediatrics Tsugaruhoken Medical COOP Kensei Hospital Hirosaki Aomori Japan.
Background: Studies on the accuracy of point-of-care (POC) testing using capillary samples are scarce. Therefore, this study aimed to assess the analytical accuracy of POC testing for white blood cell (WBC) and C-reactive protein (CRP) using capillary samples compared with conventional central laboratory testing using venous samples in a pediatric ambulatory care setting.
Methods: This was a retrospective study including patients younger than 18 years who underwent concurrent WBC and CRP evaluations via capillary and subsequent venous sampling within a 2-h window.
Prev Nutr Food Sci
December 2024
Department of Community Nutrition, Faculty of Human Ecology, IPB University, Bogor 16680, Indonesia.
This study aimed to develop tuber bread from purple sweet potato and bambara beans with high satiety and low glycemic index (GI). Different ratios of purple sweet potato to bambara bean were used: 100:0 (F0), 80:20 (F1), 60:40 (F2), and 40:60 (F3). The satiety index (SI) was determined by assessing the consumption of a 240 kcal isocaloric food and collecting data through a visual analog scale.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical Engineering, California Polytechnic State University, San Luis Obispo, California, USA.
Accurate and continuous blood glucose monitoring is essential for effective diabetes management, yet traditional finger pricking methods are often inconvenient and painful. To address this issue, photoplethysmography (PPG) presents a promising non-invasive alternative for estimating blood glucose levels. In this study, we propose an innovative 1-second signal segmentation method and evaluate the performance of three advanced deep learning models using a novel dataset to estimate blood glucose levels from PPG signals.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!