Three-dimensional (3D) imaging is an important tool for diagnostics, surgical planning, and evaluation of surgical outcomes in craniofacial procedures. Gold standard for acquiring 3D imaging is computed tomography that entails ionizing radiations and, in young children, a general anaesthesia. Three-dimensional photographic imaging is an alternative method to assess patients who have undergone calvarial reconstructive surgery. The aim of this study was to assess the utility of 3D handheld scanning photography in a cohort of patients who underwent spring-assisted correction surgery for scaphocephaly. Pre- and postoperative 3D scans acquired in theater and at the 3-week follow-up in clinic were postprocessed for 9 patients. Cephalic index (CI), head circumference, volume, sagittal length, and coronal width over the head at pre-op, post-op, and follow-up were measured from the 3D scans. Cephalic index from 3D scans was compared with measurements from planar x-rays. Statistical shape modeling (SSM) was used to calculate the 3D mean anatomical head shape of the 9 patients at the pre-op, post-op, and follow-up. No significant differences were observed in the CI between 3D and x-ray. Cephalic index, volume, and coronal width increased significantly over time. Mean shapes from SSM visualized the overall and regional 3D changes due to the expansion of the springs in situ. Three-dimensional handheld scanning followed by SSM proved to be an efficacious and practical method to evaluate 3D shape outcomes after spring-assisted cranioplasty in individual patients and the population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0000000000003108 | DOI Listing |
Data Brief
February 2025
Woodwell Climate Research Center, 149 Woods Hole Rd., Falmouth, MA, 02540, United States.
This near-infrared spectral dataset consists of 2,106 diverse mineral soil samples scanned, on average, on six different units of the same low-cost commercially available handheld spectrophotometer. Most soil samples were selected from the USDA NRCS National Soil Survey Center-Kellogg Soil Survey Laboratory (NSSC-KSSL) soil archives to represent the diversity of mineral soils (0-30 cm) found in the United States, while 90 samples were selected from Ghana, Kenya, and Nigeria to represent available African soils in the same archive. All scanning was performed on dried and sieved (<2 mm) soil samples.
View Article and Find Full Text PDFAdv Radiat Oncol
February 2025
Department of Pharmacology and Cancer Biology, Duke University Medical Center, Durham, North Carolina.
Purpose: Optimal treatment of retroperitoneal sarcoma (RPS) remains undefined. Here, we report the feasibility of using high-dose boost radiation (3-4 Gy) to the central part of the tumor in patients with unresectable RPS.
Methods And Materials: Five patients with unresectable RPS were treated with radiation therapy using a central boost technique with intensity modulated radiation therapy.
Heliyon
January 2025
BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Australia.
Breast-conserving surgery accompanied by adjuvant radiotherapy is the standard of care for patients with early-stage breast cancer. However, re-excision is reported in 20-30 % of cases, largely because of close or involved tumor margins in the specimen. Several intraoperative tumor margin assessment techniques have been proposed to overcome this issue, however, none have been widely adopted.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Intelligent Systems & Robotics, Chungbuk National University, Cheongju 28644, Republic of Korea.
Handheld LiDAR scanners, which typically consist of a LiDAR sensor, Inertial Measurement Unit, and processor, enable data capture while moving, offering flexibility for various applications, including indoor and outdoor 3D mapping in fields such as architecture and civil engineering. Unlike fixed LiDAR systems, handheld devices allow data collection from different angles, but this mobility introduces challenges in data quality, particularly when initial calibration between sensors is not precise. Accurate LiDAR-IMU calibration, essential for mapping accuracy in Simultaneous Localization and Mapping applications, involves precise alignment of the sensors' extrinsic parameters.
View Article and Find Full Text PDFANZ J Surg
December 2024
Royal Prince Alfred Institute of Academic Surgery, Sydney Local Health District, Sydney, New South Wales, Australia.
Background: Facial prosthetics are an important means to rehabilitate patients with congenital or acquired facial defects. However, with a time-consuming manual workflow and workforce shortage, access to facial prosthetics is limited in Australia and worldwide, especially for rural and remote patients. Optical 3D scanning has been increasingly integrated in digitizing data.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!