This is the first larger study analyzing the use of magnesium-based screws for fixation of modified Chevron osteotomies in hallux valgus surgery. Forty-four patients (45 feet) were included in this prospective study. A modified Chevron osteotomy was performed on every patient and a magnesium screw used for fixation. The mean clinical follow up was 21.4 weeks. The mean age of the patients was 45.5 years. Forty patients could be provided with the implant, in four patients the surgeon decided to change to a standard metallic implant. The AOFAS, FAAM and pain NRS-scale improved markedly. The hallux valgus angle, intermetatarsal angle and sesamoid position improved significantly. Seven patients showed dorsal subluxation, rotation or medial shifting of the metatarsal heads within the first 3 months. One of these patients was revised, in all others the findings were considered clinically not significant or the patients refused revision. This study shows the feasibility of using magnesium screws in hallux valgus-surgery. Surgeons starting with the use of these implants should be aware of the proper handling of these implants and should know about corrosion effects during healing and its radiographic appearance. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2207-2214, 2016.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.23241 | DOI Listing |
J Foot Ankle Surg
January 2025
Department of Orthopaedics, Peking University First Hospital Taiyuan Hospital (Taiyuan Central Hospital), Taiyuan, Shanxi Province, People's Republic of China, 030000. Electronic address:
The definitive guideline for the osteotomy technique or the superiority of a particular surgical approach for severe hallux valgus correction remains elusive. Here, we investigated the clinical and radiographic outcomes following modified distal chevron osteotomy coupled with proximal Akin osteotomy to correct severe hallux valgus. A prospective cohort study was performed on 45 patients (62 feet) diagnosed with severe hallux valgus, undergoing the modified distal chevron osteotomy technique described in this study, combined with proximal Akin osteotomy.
View Article and Find Full Text PDFJ Biomech
January 2025
School of Mechanical and Aerospace Engineering, Jilin University, Changchun 130025 PR China.
Researchers have modified PLA materials to enhance their mechanical properties and meet the clinical requirements. However, the strength and stiffness of PLA are still significantly lower than those of metals. Building on the established chevron clinical procedure and considering the mechanical characteristics of PLA screws, we devised a modified chevron osteotomy (MCO) based on a load-reducing structure with the aim of reducing the load on the screws.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Orthopedic Surgery, China Medical University Hospital, China Medical University, No. 2, Xueshi Rd., North Dist., Taichung City 404, Taiwan.
: Hallux valgus is a common forefoot disorder with hundreds of proposed management techniques. Distal chevron osteotomy with a modified McBride procedure has been traditionally recommended for mild hallux valgus because of its simple and less invasive nature with fewer complications, faster recovery, and reliable outcomes. In recent years, the indications for this procedure have expanded to include hallux valgus with severe deformities.
View Article and Find Full Text PDFACS Omega
September 2024
Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain.
In this study, we have developed a nanostructured electrochemical sensor based on modified graphene nanoribbons tailored for the analysis of nonelectroactive compounds via a surface competitive assay. Stigmasterol, a nonelectroactive phytosterol, was selected as a representative case. Chevron-like graphene nanoribbons, chemically synthesized, were immobilized onto glassy carbon electrodes and covalently functionalized to allow the on-surface formation of a supramolecular complex.
View Article and Find Full Text PDFZhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
September 2024
Department of Foot and Ankle Surgery, Shenzhen Pingle Orthopedics Hospital (Shenzhen Pingshan Traditional Chinese Medicine Hospital), Shenzhen Guangdong, 518118, P. R. China.
Objective: To explore early effectiveness of modified minimally invasive Chevron-Akin (MICA) osteotomy in the treatment of moderate to severe hallux valgus.
Methods: A clinical data of 49 patients (61 feet) with moderate to severe hallux valgus, who met the selection criteria between December 2019 and October 2022, was retrospectively analyzed. There were 7 males (8 feet) and 42 females (53 feet) with an average age of 38.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!