Dry electrodes are becoming popular for both lab-based and consumer-level electrophysiological-recording technologies because they better afford the ability to move traditional lab-based research into the real world. It is unclear, however, how dry electrodes compare in data quality to traditional electrodes. The current study compared three EEG electrode types: (a) passive-wet electrodes with no onboard amplification, (b) actively amplified, wet electrodes with moderate impedance levels, and low impedance levels, and (c) active-dry electrodes with very high impedance. Participants completed a classic P3 auditory oddball task to elicit characteristic EEG signatures and event-related potentials (ERPs). Across the three electrode types, we compared single-trial noise, average ERPs, scalp topographies, ERP noise, and ERP statistical power as a function of number of trials. We extended past work showing active electrodes' insensitivity to moderate levels of interelectrode impedance when compared to passive electrodes in the same amplifier. Importantly, the new dry electrode system could reliably measure EEG spectra and ERP components comparable to traditional electrode types. As expected, however, dry active electrodes with very high interelectrode impedance exhibited marked increases in single-trial and average noise levels, which decreased statistical power, requiring more trials to detect significant effects. This power decrease must be considered as a trade-off with the ease of application and long-term use. The current results help set constraints on experimental design with novel dry electrodes, and provide important evidence needed to measure brain activity in novel settings and situations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/psyp.12536 | DOI Listing |
ACS Omega
January 2025
Department of Chemical and Biological Engineering, The University of British Columbia, 2360 East Mall, Vancouver V6T 1Z3, Canada.
The electrochemical carbon dioxide reduction reaction (CORR) using renewable electricity sources could provide a sustainable solution for generating valuable chemicals, such as formate salt or formic acid. However, an efficient, stable, and scalable electrode generating formate at industrially viable current densities (>100 mA cm) is yet to be developed. Sn or In-based catalysts in gas diffusion electrodes (GDE) can efficiently produce formate.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
Key Laboratory for Biobased Materials and Energy of Ministry of Education, College of Materials and Energy, South China Agricultural University, No. 483 Wushan Road, Guangzhou, 510642, China.
Carbon-based perovskite solar cells (C-PSCs) have the advantages of high stability and low cost, but their mean efficiency has become an obstacle to commercialization. Defects, which are widely distributed on the surface and bulk of films, are an important factor in C-PSCs for low efficiency. The conventional post-treatment method through forming a low-dimensional (LD) perovskite layer usually fails in manipulating the bulk defects.
View Article and Find Full Text PDFJ Family Med Prim Care
December 2024
Department of Neonatology, All India Institute of Medical Science, Jodhpur, Rajasthan, India.
Context: Heart rate (HR) is the most vital parameter to assess hemodynamic transition at birth. ECG is considered a gold standard for HR assessment. New devices with dry electrodes are easy to apply on a wet newborn.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Abu Dhabi Maritime Academy, Abu Dhabi P.O. Box 54477, United Arab Emirates.
Electroencephalography (EEG) has emerged as a pivotal tool in both research and clinical practice due to its non-invasive nature, cost-effectiveness, and ability to provide real-time monitoring of brain activity. Wearable EEG technology opens new avenues for consumer applications, such as mental health monitoring, neurofeedback training, and brain-computer interfaces. However, there is still much to verify and re-examine regarding the functionality of these devices and the quality of the signal they capture, particularly as the field evolves rapidly.
View Article and Find Full Text PDFBrain Sci
November 2024
Brain.Space, Tel Aviv 58855, Israel.
Background: Electroencephalogram (EEG) biomarkers with adequate sensitivity and specificity to reflect the brain's health status can become indispensable for health monitoring during prolonged missions in space. The objective of our study was to assess whether the basic features of the posterior dominant rhythm (PDR) change under microgravity conditions compared to earth-based scalp EEG recordings.
Methods: Three crew members during the 16-day AXIOM-1 mission to the International Space Station (ISS), underwent scalp EEG recordings before, during, and after the mission by means of a dry-electrode self-donning headgear designed to support long-term EEG recordings in space.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!