A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Scanning electron microscopic evaluation of the influence of manual and mechanical glide path on the surface of nickel-titanium rotary instruments in moderately curved root canals: An study. | LitMetric

Aim: The aim of this study was to evaluate the influence of manual versus mechanical glide path (GP) on the surface changes of two different nickel-titanium rotary instruments used during root canal therapy in a moderately curved root canal.

Materials And Methods: Sixty systemically healthy controls were selected for the study. Controls were divided randomly into four groups: Group 1: Manual GP followed by RaCe rotary instruments, Group 2: Manual GP followed by HyFlex rotary instruments, Group 3: Mechanical GP followed by RaCe rotary instruments, Group 4: Mechanical GP followed by HyFlex rotary instruments. After access opening, GP was prepared and rotary instruments were used according to manufacturer's instructions. All instruments were evaluated for defects under standard error mean before their use and after a single use. The scorings for the files were given at apical and middle third.

Statistical Analysis Used: Chi-squared test was used.

Results: The results showed that there is no statistical difference between any of the groups. Irrespective of the GP and rotary files used, more defects were present in the apical third when compared to middle third of the rotary instrument.

Conclusion: Within the limitations of this study, it can be concluded that there was no effect of manual or mechanical GP on surface defects of subsequent rotary file system used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146771PMC
http://dx.doi.org/10.4103/0972-0707.194035DOI Listing

Publication Analysis

Top Keywords

rotary instruments
28
instruments group
12
rotary
10
influence manual
8
manual mechanical
8
mechanical glide
8
glide path
8
path surface
8
nickel-titanium rotary
8
instruments
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!