A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Ultrasound-Guided Intra-articular Hip Injections Performed in the Orthopedic Clinic. | LitMetric

Intra-articular hip injections have proven clinical value for both diagnostic and therapeutic purposes. Historically, these injections have been performed by radiologists using fluoroscopic guidance. This necessitates a radiology referral, delays the injection, and represents lost productivity for the orthopedist. Ultrasound-guided intra-articular hip injections have been described in the radiology literature with excellent accuracy. These injections were performed by radiologists. The purpose of this study was to determine the accuracy of ultrasound-guided hip injections performed in the orthopedic clinic by orthopedic surgeons and orthopedic physician assistants. Fifty ultrasound-guided hip injections were performed using a standard technique. Contrast was included, and an anteroposterior pelvis radiograph was obtained immediately following injection. Diagnosis, body mass index, procedure time, and visual analog scale scores were recorded. Radiographs were reviewed independently by a musculoskeletal radiologist and an orthopedic surgeon to determine intra-articular placement of the injection. A total of 50 hips were injected. There was no identifiable contrast in 2 patients, leaving 48 hips for analysis. Of these, contrast was injected intra-articularly in 46 hips for an accuracy of 96%. Average procedural time was 2.6 minutes, and the average visual analog scale score was 1.9 during the procedure. Revenue value units ranged from 1.72-2.55 for ultrasound-guided hip injections. These findings indicate ultrasound-guided intra-articular hip injections performed in the orthopedic clinic by surgeons or physician assistants are accurate, efficient, and patient-friendly. Additionally, they preserve patient continuity and maintain productivity within the orthopedic clinic. [Orthopedics. 2017; 40(2):96-100.].

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20161213-03DOI Listing

Publication Analysis

Top Keywords

hip injections
28
injections performed
24
intra-articular hip
16
orthopedic clinic
16
ultrasound-guided intra-articular
12
performed orthopedic
12
ultrasound-guided hip
12
injections
9
accuracy ultrasound-guided
8
performed radiologists
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!