The naviculocuneiform articulation is composed of the navicular proximally and the 3 cuneiforms distally. It is not uncommon to perform surgical interventions at this joint for multiple pathologic foot etiologies. To date, no detailed anatomic measurement is available for each cuneiform articulation on the navicular. The purpose of the present study was to present an anatomic description of this complex joint to aid in better surgical understanding and improve surgical outcomes. Ten fresh, frozen, and thawed below-the-knee cadaveric specimens were used for anatomic dissection of the navicular and associated cuneiforms. The height and width were recorded across the largest span of the entire navicular-cuneiform joint complex and each facet. The mean navicular height and width was 19.9 mm and 34.7 mm, respectively. The medial cuneiform facet mean height and width was 19.9 mm and 15.8 mm, respectively. The intermediate cuneiform facet mean height and width was 20.4 mm and 16.9 mm, respectively. The lateral cuneiform facet mean height and width was 17.5 mm and 14.7 mm, respectively. A detailed description of this joint complex will aid foot and ankle surgeons in screw placement and surgical decision-making when performing complex medial column fusions. Advanced 3-dimensional weightbearing computed tomography would give us a better idea of the motion that occurs within this complex joint.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/j.jfas.2016.09.013 | DOI Listing |
Int J Pharm
December 2024
Department of Pharmaceutical Engineering, Azrieli College of Engineering Jerusalem, Jerusalem 9103501, Israel. Electronic address:
Chlorhexidine (CHX) is a gold standard therapeutic agent against clinical oral pathogens. However, its oral use is limited due to unpleasant taste, alteration in taste buds, staining of teeth and mucous membranes. Therefore, CHX-loaded PLGA microneedles (MNs) were fabricated for local and controlled release in the oral cavity, using a casting mold method.
View Article and Find Full Text PDFGels
December 2024
Research Institute of Smart Medicine and Biological Engineering, Health Science Center, Ningbo University, Ningbo 315211, China.
Many tissues exhibit structural anisotropy, which imparts orientation-specific properties and functions. However, recapitulating the cellular patterns found in anisotropic tissues presents a remarkable challenge, particularly when using soft and wet hydrogels. Herein, we develop self-assembled anisotropic magnetic FeO micropatterns on polyethylene glycol hydrogels utilizing dipole-dipole interactions.
View Article and Find Full Text PDFNanoscale Adv
December 2024
Department of Electrical and Electronic Engineering, Rajshahi University of Engineering & Technology Rajshahi-6204 Bangladesh
With advancements in photonic technologies, photonic crystal fibers (PCFs) have become crucial components in developing highly sensitive and efficient biosensors. This paper presents an optimized bowtie-shaped PCF biosensor that leverages surface plasmon resonance (SPR) phenomena for enhanced refractive index (RI) sensing. The proposed design uses an external sensing mechanism to effectively characterize performance across an RI range of 1.
View Article and Find Full Text PDFShanghai Kou Qiang Yi Xue
October 2024
Shihezi University School of Medicine; Department of Prosthodontics, Urumqi Stomatological Hospital. Urumqi 830002, Xinjiang Uygur Autonomous Region, China. E-mail:
Purpose: To analyze the effect of n-HA/chitosan/minocycline composite scaffold in the animal model of peri-implant inflammatory bone defect.
Methods: Twelve healthy adult male beagle dogs were selected to construct the model of peri-implant inflammatory bone defect. The control group(n=6) underwent bone regeneration by alveolar self-healing without any treatment in the bone defect area.
Acta Ophthalmol
December 2024
Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, China.
Purpose: To evaluate the long-term effects of implantable collamer lens (ICL) V4c on the biomechanical and morphological properties of crystalline lenses in Chinese adults with high myopia using Brillouin microscopy (BM).
Methods: In this case-control study, 102 highly myopic eyes from 102 patients (18-48 years, preoperative spherical equivalent (SE): -6.00--21.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!