In the present study, various electrochemical tests were used to investigate the passive and electrochemical response of annealed and nano-grained commercial pure Titanium in Ringer's physiological solution at 37°C. Nano-grained pure Titanium, which typically has an average grain size of 90±5nm, was obtained by six-cycle accumulative roll bonding process. Polarization and electrochemical impedance spectroscopy plots illustrated that as a result of grain refinement process, the passive response of the nano-grained sample was improved compared to that of its coarse-grained counterpart in Ringer's physiological solution. Mott-Schottky analysis indicated that the passive films behaved as n-type semiconductors in Ringer's physiological solution and grain refinement did not change the conductivity type of the passive films. Additionally, Mott-Schottky analysis showed that the donor density decreased by grain size reduction. Finally, nano-grained sample appeared to be more suitable for implant applications, mainly due to the formation of thicker and less defective oxide film.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2016.10.057DOI Listing

Publication Analysis

Top Keywords

ringer's physiological
16
physiological solution
16
pure titanium
12
passive electrochemical
8
electrochemical response
8
response annealed
8
annealed nano-grained
8
nano-grained commercial
8
commercial pure
8
titanium ringer's
8

Similar Publications

A comparative study of storage solutions on the biomechanical preservation of human saphenous veins.

J Biomech

January 2025

Department of Mechanics & Engineering, College of Architecture & Environment, Sichuan University, Chengdu 610065, China; Med-X Center for Informatics, Sichuan University, Chengdu, 610041, China. Electronic address:

Storage solutions have a significant impact on the physiological properties of saphenous veins (SV), yet their effects on the biomechanics remained unclear. This study investigated how different storage solutions affect the biomechanical properties of SV. The goal was to find a solution that minimally impacts SV biomechanics, providing an effective method for SV preservation.

View Article and Find Full Text PDF

Background: Poly(glycerol sebacate) is a polymeric material with potential biomedical application in the field of tissue engineering. In order to act as a biodegradable scaffold, its incubation study is vital to simulate its behavior.

Objectives: This study explores the degradation of porous poly(glycerol sebacate)/hydroxyapatite scaffolds subjected to incubation in various physiological solutions.

View Article and Find Full Text PDF

Introduction The relationship between pre-hospital intravenous (IV) infusions administered by emergency life-saving technicians (ELSTs) to trauma patients in shock and the resulting variability in their vital signs before hospital arrival remains unclear. In 2014, Japan approved the use of lactated Ringer's solution via IV by ELSTs for patients aged 15 and older with non-cardiac arrest and shock symptoms not caused by cardiogenic factors. However, the impact of pre-hospital IV infusions on physiological parameters in severely injured trauma patients is still unknown.

View Article and Find Full Text PDF

The process of osteointegration depends significantly on the surface roughness, structure, chemical composition, and mechanical characteristics of the coating. In this regard, an important direction in the development of medical materials is the development of new techniques of surface modification and the creation of bioactive ceramic coatings. Calcium-phosphate materials based on hydroxyapatite have been proposed as bioactive ceramic coatings on titanium implants for the effective acceleration of bone tissue healing.

View Article and Find Full Text PDF

We developed the LabVIEW-based virtual instruments (VIs) to bridge a gap in commercial software and to enable systematic peak-overlapping studies to recognise the concentration levels enabling reliable simultaneous determination of major and minor constituents in samples with wide concentration proportions. The VIs were applied to a case study of the ion chromatographic determination of potassium as minor and sodium as a major ion with an IonPac CS12A column and 50 μL injection loop. Two successive studies based on multilevel two-factorial response surface experimental designs, (1) a model peak-overlapping study based on single-ion injections, and (2) an accuracy and precision study, provided guidelines for real sample analyses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!