A novel nanoparticles impregnated ocular insert for enhanced bioavailability to posterior segment of eye: In vitro, in vivo and stability studies.

Mater Sci Eng C Mater Biol Appl

Drug Delivery Research Laboratory, Centre of relevance and Excellence in NDDS, Faculty of Pharmacy, The Maharaja Sayajirao University of Baroda, Donor's Plaza, Fatehgunj, Vadodara 390002, India. Electronic address:

Published: February 2017

The present investigation was carried out to demonstrate with the help of in vitro and in vivo studies that nanoparticles impregnated ocular inserts effectively delivers significant concentration of drug to the posterior segment of eye after topical administration for treatment of glaucoma. Drug loaded Nanoparticles and their ocular insert have been reported to reduce side effects of orally administered Acetazolamide. Eudragit NPs were prepared by the solvent diffusion nanoprecipitation technique. The prepared NPs were evaluated for various parameters such as particle size, zeta potential, % entrapment efficiency, % drug loading, DSC, FTIR, TEM and stability studies. Ocular inserts of NPs were prepared by solvent casting method. The prepared ocular inserts were evaluated for thickness, content uniformity, folding endurance, disintegration time, morphology and stability study. The NPs and ocular inserts were evaluated for in-vitro drug diffusion study, ex-vivo trans-corneal permeability study, in-vivo ocular tolerability and intra ocular pressure (IOP) reduction study. The optimized batch was stable for a period of 3months in lyophilized form. The optimized formulations had size range of 367nm±8nm, zeta potential around +7mV±1.3mV and 51.61%±3.84% entrapment efficiency with 19%±1.40% drug loading. The ex-vivo trans-corneal study showed higher cumulative corneal permeation, flux across corneal tissue (2.460±0.028μg/ml) and apparent corneal permeability (3.926×10cm/s & 3.863×10cm/s) from drug loaded Eudragit NPs and Ocular inserts as compared to drug solution (0.671±0.020μg/ml & 3.166×10cm/s). In-vivo study showed the Eudragit NPs and ocular insert produced significant (P<0.001) lowering in intra ocular pressure compared with the solution of free drug after 3h of topical ocular administration. Plain Eudragit NPs caused no inflammation and/or discomfort in rabbit eyes and neither affected the intra ocular pressure establishing their safety and non irritancy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2016.10.017DOI Listing

Publication Analysis

Top Keywords

ocular inserts
20
ocular insert
12
eudragit nps
12
nps ocular
12
ocular
10
nanoparticles impregnated
8
impregnated ocular
8
posterior segment
8
segment eye
8
vitro vivo
8

Similar Publications

Purpose: This study aimed to identify a novel recombinant adeno-associated virus (rAAV) capsid variant that can widely transfect the deep retina through intravitreal injection and to assess their effectiveness and safety in gene delivery.

Methods: By adopting the sequences of various cell-penetrating peptides and inserting them into the capsid modification region of AAV2, we generated several novel variants. The green fluorescent protein (GFP)-carrying variants were screened following intravitreal injection.

View Article and Find Full Text PDF

Background: The ciliary muscle is known to play a part in presbyopia, but the mechanism has not received a comprehensive review, which this study aims to achieve. We examined relevant articles published from 1975 through 2022 that explored various properties of the muscle and related tissues in humans and rhesus monkeys. These properties include geometry, elasticity, rigidity, and composition, and were studied using a range of imaging technologies, computer models, and surgical methods.

View Article and Find Full Text PDF

Scleral-fixated intraocular lens (SFIOL) is a widely used technique for IOL implantation in patients where capsular support is insufficient. Most surgeons have shifted away from sutured to sutureless SFIOL techniques where haptics of a multifocal IOL are inserted in scleral tunnels/flaps. Large-scale publications have shown wide variation in the refractive status of eyes post-SFIOL even in the best of the hands.

View Article and Find Full Text PDF

Purpose: To investigate sensitivity of contributing factors to heterogeneity corrections in ocular brachytherapy using iodine-125 (I) Collaborative Ocular Melanoma Study (COMS) plaques.

Material And Methods: Using egs_brachy, Monte Carlo (MC) simulations were performed for I COMS plaques (model: IsoAid IAI-125A). Homogeneous dose (D) was estimated under the American Association of Physicists in Medicine Task Group-43 assumptions, with 85 Gy prescribed to a 5 mm depth.

View Article and Find Full Text PDF

Background: Adequate health literacy has been shown to be important for the general health of a population. To address this, it is recommended that patient-targeted medical information is written at a sixth-grade reading level. To make well-informed decisions about their health, patients may want to interact directly with peer-reviewed open access scientific articles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!