Electroencephalography (EEG) is a common neuroscience technique that is more accessible to undergraduate programs than expensive techniques such as fMRI and single-cell recording. The use of EEG can provide undergraduates with firsthand neuroscience research experience without taking too many financial resources away from a program. There are multiple types of EEG equipment that can be used, including individual electrodes and electrode caps. This study used surveys administered to students who were in a neuroscience laboratory course, conducting research, or participating in research in order to discern which of these two EEG setups is preferred by undergraduates. According to average reaction scores calculated from the surveys, laboratory students tended to prefer individual electrodes over electrode caps, and when explicitly asked about their overall preference, a majority of laboratory students chose individual electrodes over electrode caps. Additionally, comparable levels of improvement in learning objectives and the quality of data collected in laboratory sessions were found across methods. Student researchers' ratings revealed a marginal preference for caps over individual electrodes, and all 5 researchers surveyed chose caps on a discriminate choice question. Research participants' ratings of caps and individual electrodes, however, were not significantly different. These results do not point to a concrete recommendation of one setup over the other but rather suggest that either setup could be a viable option. Therefore, we conclude that programs can comfortably decide which to use based on their own needs and resources as well as the relative advantages and disadvantages of each setup. For example, individual electrodes may be better for programs with low budgets looking to introduce students to EEG data recording, whereas electrode caps may be better for programs looking to better prepare students for future EEG research or to perform multichannel recordings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5105961 | PMC |
Exp Brain Res
January 2025
Department of Rehabilitation Medicine, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, 510080, China.
Vestibular dysfunction has been reported as a potential cause in adolescent idiopathic scoliosis (AIS). However, it remained unclear how stochastic galvanic vestibular stimulation (GVS) affected kinetic performance of patients with AIS. This study aimed to investigate the effect of stochastic GVS on ground reaction forces (GRF) measures during obstacle negotiation among patients with AIS.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Department of Cardiology, Xuzhou Central Hospital, No.199 Jiefang South Road, Quanshan District, Xuzhou, 221009, People's Republic of China.
Background: The aim of this study is to identify factors associated with the development of long-term severe tricuspid regurgitation (TR) following mitral valve replacement (MVR).
Methods: A retrospective analysis was conducted involving 308 patients who underwent single-valve MVR at Xuzhou Central Hospital between April 2017 and December 2022. Preoperative color Doppler ultrasound indicated that all patients had either no or mild to moderate tricuspid regurgitation.
Eur Arch Otorhinolaryngol
January 2025
Department of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.
Purpose: Evaluate the feasibility and safety of a robotic electrode insertion in pediatric cochlear implantation and compare the results with manually inserted electrodes in the same subject.
Methods: Retrospective case series review of four children who underwent bilateral cochlear implantation with the same array: on one side, the array was inserted using the robot, while on the other side the array was inserted manually. Behavioural and electrophysiological measures were compared.
PLoS One
January 2025
National Heart and Lung Institute, Imperial College London, London, United Kingdom.
Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.
Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.
Cell Rep
January 2025
Centre for Systems Neuroscience, University of Leicester, Leicester, UK; Hospital Del Mar Medical Research Institute (IMIM), Barcelona, Spain; Institució Catalana de Recerca I Estudis Avançats (ICREA), Barcelona, Spain; Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Electronic address:
In subjects implanted with intracranial electrodes, we use two different stories involving the same person (or place) to evaluate whether and to what extent context modulates human single-neuron responses. Nearly all neurons (97% during encoding and 100% during recall) initially responding to a person/place do not modulate their response with context. Likewise, nearly none (<1%) of the initially non-responsive neurons show conjunctive coding, responding to particular persons/places in a particular context during the tasks.