A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automatic determination of coenzyme Q10 in food using cresyl violet encapsulated into magnetoliposomes. | LitMetric

Automatic determination of coenzyme Q10 in food using cresyl violet encapsulated into magnetoliposomes.

Food Chem

Analytical Chemistry Department, Institute of Fine Chemistry and Nanochemistry, Campus of Rabanales, Annex to Marie Curie Building, University of Córdoba, 14071 Córdoba, Spain. Electronic address:

Published: April 2017

AI Article Synopsis

  • A new type of magnetoliposomes (MLs) was developed for detecting coenzyme Q10 (CoQ10), using hydrophobic magnetic-gold nanoparticles and a fluorophore called cresyl violet.
  • The MLs are concentrated prior to detection through a flow system and an electromagnet, and their lysis through Triton X-100 leads to a decrease in fluorescence that indicates CoQ10 levels.
  • The method allows for accurate measurements in food samples, with a calibration range of 0.03-0.50 μmol/L, a detection limit of 0.008 μmol/L, and recovery rates between 83.5-101.3% when compared to traditional chromatographic techniques.

Article Abstract

A new type of magnetoliposomes (MLs), containing hydrophobic magnetic-gold nanoparticles and the long wavelength fluorophore cresyl violet, has been used for the determination of coenzyme Q10 (CoQ10). MLs were concentrated just before the detector, using a flow system and an external electromagnet device. The subsequent introduction of Triton X-100 and CoQ10 causes the MLs lysis and the cresyl violet oxidation, obtaining a decrease in the fluorescence signal. The dynamic range of the calibration graph was 0.03-0.50μmolL CoQ10, and the detection limit was 0.008μmolL. The precision (relative standard deviation) was in the range of 1.3-4.5%. The method showed a sampling frequency of 12h and was applied to the determination of CoQ10 in several food samples. The results were compared with those obtained using a previously described chromatographic method. Also, recovery values were in the range of 83.5-101.3%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2016.11.085DOI Listing

Publication Analysis

Top Keywords

cresyl violet
12
determination coenzyme
8
coenzyme q10
8
coq10 mls
8
automatic determination
4
q10 food
4
food cresyl
4
violet encapsulated
4
encapsulated magnetoliposomes
4
magnetoliposomes type
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!