A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Single-institution Experience with Open Irreversible Electroporation for Locally Advanced Pancreatic Carcinoma. | LitMetric

Background: Locally advanced pancreatic carcinoma (LAPC) is characterized by poor prognosis despite recommended concurrent chemoradiotherapy. Irreversible electroporation (IRE) has emerged as a potential option for the management of unresectable pancreatic cancer. This study was conducted to evaluate the safety and short-term efficacy of open IRE for the treatment of LAPC.

Methods: Retrospective data of 25 consecutive patients receiving IRE for T3 lesions from July 2015 to June 2016 at a single center were analyzed. The perioperative and long-term IRE-related complications were reviewed to evaluate the safety of the procedure. The tumor reduction and biological response were analyzed through computed tomography/magnetic resonance imaging; the serum level of CA19-9 was measured as a secondary endpoint to evaluate the short-term efficacy of IRE.

Results: All patients were successfully treated; the median tumor size was 4.2 cm and the median IRE time was 36 min. Four intraoperative procedure-related complications were observed (16%): two transient hypertensive episodes, one hypotension case, and one transient supraventricular tachycardia case. Nine postoperative complications were described, including three Grade A pancreatic fistulas, three delayed gastric emptying, one acute pancreatitis, one upper gastrointestinal hemorrhage, and one portal vein thrombosis. The overall rate of stable disease was 28%, 36% achieved partial response, and lower serum CA19-9 levels were recorded in all patients at discharge.

Conclusions: IRE is feasible for the treatment of LAPC and is a reasonable intervention strategy owing to its combined attributes of safety and efficacy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5198526PMC
http://dx.doi.org/10.4103/0366-6999.195476DOI Listing

Publication Analysis

Top Keywords

irreversible electroporation
8
locally advanced
8
advanced pancreatic
8
pancreatic carcinoma
8
evaluate safety
8
short-term efficacy
8
ire
5
single-institution experience
4
experience open
4
open irreversible
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!