Novel reference electrodes with a solid contact coated by a heterogeneous polymer membrane are described. The electrodes are obtained using Ag nanoparticles, AgBr, KBr suspended in tetrahydrofuran solution of PVC and DOS and deposited on Ag substrate, or another substrate covered with Ag, by drop casting. After a short period of soaking in a KBr solution, stable and reproducible formal potentials of -157 ± 2 mV (vs Ag/AgCl/3 M KCl) were observed, and the solid-contact reference electrodes were ready to use. It is shown that the described reference electrodes are relatively insensitive to the changes in the sample matrix, the concentrations of ions, the pH and the redox potential. These electrodes can also be fabricated in miniaturized form, and thus used to produce miniaturized multielectrode probes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.6b02762 | DOI Listing |
Front Neurorobot
January 2025
College of Engineering, Qufu Normal University, Rizhao, China.
Brain-computer interfaces (BCIs) have garnered significant research attention, yet their complexity has hindered widespread adoption in daily life. Most current electroencephalography (EEG) systems rely on wet electrodes and numerous electrodes to enhance signal quality, making them impractical for everyday use. Portable and wearable devices offer a promising solution, but the limited number of electrodes in specific regions can lead to missing channels and reduced BCI performance.
View Article and Find Full Text PDFPLoS One
January 2025
Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland.
Electroencephalographic signals are obtained by amplifying and recording the brain's spontaneous biological potential using electrodes positioned on the scalp. While proven to help find changes in brain activity with a high temporal resolution, such signals are contaminated by non-stationary and frequent artefacts. A plethora of noise reduction techniques have been developed, achieving remarkable performance.
View Article and Find Full Text PDFCochrane Database Syst Rev
January 2025
Department of Pharmacy Practice, University of Connecticut, Storrs, CT 06269, USA.
Background: Guideline-recommended strategies to interrupt chronic anticoagulation with warfarin or direct oral anticoagulants (DOAC) during the perioperative period of cardiac implantable electronic device (CIED) surgery differ worldwide. There is uncertainty concerning the benefits and harms of interrupted and uninterrupted anticoagulation in patients undergoing CIED surgery.
Objectives: To assess the benefits and harms of interrupted anticoagulation (IAC) with either warfarin or DOAC in the perioperative period of CIED surgery versus uninterrupted anticoagulation (UAC), with or without heparin bridging, during an equivalent time frame, for CIED surgery.
Angew Chem Int Ed Engl
January 2025
Aarhus University, iNANO, Department of Chemistry, Langelandsgade 140, 8000, Aarhus C, DENMARK.
Solid-state batteries created from abundant elements, such as calcium, may pave the way for cheaper and safer electrical energy storage. Here we report a new type of solid calcium hydridoborate electrolyte, Ca(BH4)2·2NH2CH3, with a high ionic conductivity of σ(Ca2+) ~ 10-5 S cm-1 at T = 70 °C, which is assigned to a relatively open and flexible structure with apolar moieties and weak dihydrogen bonds that facilitate migration of Ca2+ ions in the solid state. The compound display a low electronic conductivity, providing an ionic transport number close to unity (tion = 0.
View Article and Find Full Text PDFSTAR Protoc
January 2025
Department of Neurology, College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA; Initiative for Columbia Ataxia and Tremor, Columbia University, New York, NY 10032, USA. Electronic address:
As Purkinje cells of the cerebellum have a very fast firing rate, techniques with high temporal resolution are required to capture cerebellar physiology. Here, we present a protocol to record physiological signals in humans using cerebellar electroencephalography (cEEG). We describe steps for electrode placement and recording.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!