Water absorbed to poly(methyl methacrylate) (PMMA)-based CAD/CAM (computer-assisted design/computer-assisted manufacturing) prosthodontics can alter their properties including hardness and stability. In the present contribution, water absorption and desorption kinetics under defined experimental conditions were monitored employing several supplementary and advanced Fourier transform infrared (FT-IR) spectroscopic techniques in combination with multivariate analysis (MVA). In this synergistic vibrational spectroscopic multimethod approach, first a novel near-infrared (NIR) diffuse fiber optic probe reflection spectroscopic method was established for time-resolved analysis of water uptake within seven days under controlled conditions. Near-infrared water absorbance spectra in a wavenumber range between 5288-5100 cm (combination band) and 5424-5352 cm (second overtone) were used establishing corresponding calibration and validation models to quantify the amount of water in the milligram range. Therefore, 14 well-defined samples exposed to prior optimized experimental conditions were taken into consideration. The average daily water uptake conducting reference analysis was calculated as 22 mg/day for one week. Additionally, in this study for the first time NIR two-dimensional correlation spectroscopy (2D-COS) was conducted to monitor and interpret the spectral dynamics of water absorption on the prosthodontics in a wavenumber range of 5100-5300 cm. For sensitive time-resolved recording of water desorption, a recently developed high-temperature, high-pressure FT-IR reaction cell with water-free ultra-dry in situ and operando operation was applied. The reaction cell, as well as the sample holder, was fully made of quartz glass, with no hot metal or ceramic parts in the vicinity of the high temperature zone. Applying a temperature gradient in the range of 25-150 ℃, mid-infrared (MIR) 2D-COS was successfully conducted to get insights into the dynamic behavior of O-H (1400-1800 cm) absorption bands with increasing temperature over time and the release of CO (2450 cm) from the polymers. In addition, an ATR FT-IR imaging setup was optimized in order to investigate the surface homogeneity of the PMMA-based resins with a spatial resolution to 2 µm. From this vibrational spectroscopic multimethod approach and the collection of several analytical data, conclusions were drawn as to which degree the surface structure and/or its porosity have an impact onto the amount of water absorption.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0003702816682742DOI Listing

Publication Analysis

Top Keywords

spectroscopic multimethod
12
multimethod approach
12
water absorption
12
water
10
polymethyl methacrylate
8
experimental conditions
8
vibrational spectroscopic
8
water uptake
8
wavenumber range
8
amount water
8

Similar Publications

Preparation and characterization of new salts of tioconazole. Comparison of their dissolution performance.

Int J Pharm

March 2024

Área de Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario e Instituto de Química Rosario (IQUIR. CONICET-UNR), Suipacha 531, S2002LRK, Rosario, Argentina. Electronic address:

Article Synopsis
  • Tioconazole has poor solubility in water, limiting its effectiveness as an antifungal, prompting research into new crystalline salts to enhance its bioavailability.
  • Four new salts were created (mesylate, tosylate, maleate, and fumarate), with studies showing they have improved thermal stability and dissolution rates compared to the original free base and existing oxalate salt.
  • The new salts, particularly the sulfonic acid derivatives, showed significantly better solubility at pH 4.3, indicating their potential as more effective alternatives for delivering tioconazole in various applications.
View Article and Find Full Text PDF

Comprehensive spectroscopic, metabolomic, and proteomic liquid biopsy in the diagnostics of hepatocellular carcinoma.

Talanta

April 2024

Department of Analytical Chemistry, Faculty of Chemical Engineering, University of Chemistry and Technology, Prague, Technicka 5, 166 28, Prague 6, Czech Republic. Electronic address:

Liquid biopsy is a very topical issue in clinical diagnostics research nowadays. In this study, we explored and compared various analytical approaches to blood plasma analysis. Finally, we proposed a comprehensive procedure, which, thanks to the utilization of multiple analytical techniques, allowed the targeting of various biomolecules in blood plasma reflecting diverse biological processes underlying disease development.

View Article and Find Full Text PDF

The electrochemical carbon dioxide reduction reaction (CO2RR) over carbon-supported gold nanoparticles (AuNP) was investigated using a broad variety of (electro)analytical methods, including linear sweep voltammetry with a rotating disk electrode (LSV-RDE), sample-generation tip-collection mode of scanning electrochemical microscopy (SG/TC-SECM), as well as full cell tests with highly sensitive online gas chromatography (GC). In contrast to most other studies, this work focuses on the low-overpotential region (0 to -0.4 V vs RHE) where initial product formation is already detected and addresses micro- to macro-sized electrodes.

View Article and Find Full Text PDF

Localization and chemical speciation of europium(III) in Brassica napus plants.

Ecotoxicol Environ Saf

April 2023

Helmholtz-Zentrum Dresden-Rossendorf, Institute of Resource Ecology, Bautzner Landstraße 400, 01328 Dresden, Germany. Electronic address:

For the reliable safety assessment of repositories of highly radioactive waste, further development of the modelling of radionuclide migration and transfer in the environment is necessary, which requires a deeper process understanding at the molecular level. Eu(III) is a non-radioactive analogue for trivalent actinides, which contribute heavily to radiotoxicity in a repository. For in-depth study of the interaction of plants with trivalent f elements, we investigated the uptake, speciation, and localization of Eu(III) in Brassica napus plants at two concentrations, 30 and 200 µM, as a function of the incubation time up to 72 h.

View Article and Find Full Text PDF

The experimental and theoretical description of premelting behavior is one of the most challenging tasks in contemporary material science. In this paper, n-octanol was studied using a multi-method approach to investigate it at macroscopic and molecular levels. The experimental infrared (IR) spectra were collected in the solid state and liquid phase at temperature range from -84∘C to -15 ∘C to detect temperature-related indicators of pretransitional phenomena.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!