Background Flow diverter (FD) malapposition is associated with stroke-related complications. We document the use of self-expanding nitinol stents to remove/reduce the ledge of a FD deployed for aneurysm treatment. Methods We identified five patients who were treated with the Pipeline embolization device (PED) in conjunction with a Neuroform EZ stent for inadequate wall apposition of the ends of the FD at our institution between May 2014 and July 2015. Among other parameters, angiographic results, cone-beam computed tomography assessment of wall apposition and patient clinical outcome were evaluated. Results Incomplete device end apposition was seen in three cases, and precarious positioning of the distal end of the PED over the aneurysm neck was seen in two cases. In all five cases, successful treatment with good wall apposition and proper pinning of the PED distal edge was achieved using an additional Neuroform EZ stent. Appropriate aneurysm neck coverage and flow stagnation was seen in all cases. The combination of high radial outward force and open-cell design permits the Neuroform EZ stent to jail the malappositioned edges of the FD while maintaining good vessel-wall apposition itself and prevent migration of the PED. Short-term follow-up angiography showed device patency and complete aneurysm obliteration in all cases. Conclusions Preliminary results of this small case series suggest that the Neuroform EZ stent allows for effective treatment of FD malapposition in selected patients amenable for this endovascular approach. Long-term and larger cohort studies are needed to validate these results.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5433601 | PMC |
http://dx.doi.org/10.1177/1591019916681981 | DOI Listing |
JBJS Essent Surg Tech
December 2024
Department of Orthopedics, OhioHealth Health System, Columbus, Ohio.
J Comp Neurol
December 2024
Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, Florida, USA.
Cureus
October 2024
Department of Anesthesiology, Uniformed Services University of the Health Sciences, Bethesda, USA.
J Neurosurg Case Lessons
October 2024
Cooper Medical School of Rowan University, Camden, New Jersey.
Background: Iatrogenic vertebral artery injury during surgery can cause pseudoaneurysm, hemorrhage, thrombosis, ischemia, or death. Strategies to prevent cerebrovascular embolic complications include surgical ligation, endovascular stenting, and/or antiplatelet therapy.
Observations: A 73-year-old female with a known right vertebral artery occlusion underwent a C2-3 laminectomy, complicated by left vertebral artery injury and occlusion with subsequent posterior circulation ischemia.
J Neurointerv Surg
November 2024
Neuroradiology, Gui de Chauliac, University Hospital Centre of Montpellier, Montpellier, France.
Background: Virtual simulation is increasingly used for aneurysm treatment. This study aimed to explore whether mechanical behavior biomarkers of the Woven EndoBridge (WEB) device as computed by Sim&Size simulation software were associated with aneurysmal occlusion status at follow-up.
Methods: Consecutive patients with aneurysms treated with WEB were retrospectively enrolled (January 2014 to December 2021).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!