A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Solution blow spun polymer: A novel preclinical surgical sealant for bowel anastomoses. | LitMetric

Background: Solution blow spinning is a technique for depositing polymer fibers with promising potential use as a surgical sealant. This study assessed the feasibility and efficacy of solution blow spun polymer (BSP) for sealing bowel perforations in a mouse model of partial cecal transection. We then evaluated its use for reinforcing a surgical anastomosis in a preclinical piglet model.

Methods: Three commercially available surgical sealants (fibrin glue, polyethylene glycol (PEG) hydrogel, and cyanoacrylate) were compared to BSP in the ability to seal partially transected cecum in mice. For anastomosis feasibility testing in a piglet model, piglets were subjected to small bowel transection with sutured anastomosis reinforced with BSP application. Outcome measures included anastomotic burst pressure, anastomotic leak rate, 14-day survival, and complication rate.

Results: For the mouse model, the survival rates for the sealants were 30% for fibrin glue, 20% for PEG hydrogel, 78% for cyanoacrylate, and 67% for BSP. Three of 9 mice died after BSP administration because of perforation leak, failure to thrive with partial obstruction at the perforation site, and unknown causes. All other mice died of perforation leak. The mean burst pressure at 24h was significantly higher for BSP (81mm Hg) when compared to fibrin glue (6mm Hg, p=0.047) or PEG hydrogel (10mm Hg, p=0.047), and comparable to cyanoacrylate (64mm Hg, p=0.91). For piglets, 4 of 4 animals survived at 14days. Mean burst pressures at time of surgery were 37±5mm Hg for BSP and 11±9mm Hg for suture-only controls (p=0.09).

Conclusions: Solution blow spinning may be an effective technique as an adjunct for sealing of gastrointestinal anastomosis. Further preclinical testing is warranted to better understand BSP properties and alternative surgical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5459684PMC
http://dx.doi.org/10.1016/j.jpedsurg.2016.11.044DOI Listing

Publication Analysis

Top Keywords

solution blow
16
fibrin glue
12
peg hydrogel
12
blow spun
8
spun polymer
8
surgical sealant
8
blow spinning
8
bsp
8
mouse model
8
anastomosis preclinical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!