Trisulfides can be a common post-translational modification in many recombinant monoclonal antibodies. These are a source of product heterogeneity that add to the complexity of product characterization and hence, need to be reduced for consistent product quality. Trisulfide bonds can be converted to the regular disulfide bonds by incorporating a novel cysteine wash step during Protein A affinity chromatography. An empirical model is developed for this on-column reduction reaction to compare the reaction rates as a function of typical operating parameters such as temperature, cysteine concentration, reaction time and starting level of trisulfides. The model presented here is anticipated to assist in the development of optimal wash conditions for the Protein A step to effectively reduce trisulfides to desired levels.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2016.11.019 | DOI Listing |
Open Res Eur
November 2024
Civil Engineering, University of Patras, Patras, Peloponnisos Dytiki Ellada ke Ionio, 26504, Greece.
Existing steel frames not complying with modern seismic codes are often vulnerable to earthquakes due to inadequate seismic detailing. These types of framed structures typically feature semi-rigid and partial strength column-base connections; the behaviour of such connections may significantly affect their seismic performance. However, current code provisions offer limited guidance for the assessment and retrofit of column-base connections To fill the knowledge gap, the H2020 EU-funded Earthquake Assessment of Base-Column Connections in Existing Steel Frames project experimentally investigated, the response of exposed column-base plate connections.
View Article and Find Full Text PDFAiming at the problem of luminance uniformity for injection electroluminescent display panels, we present a new sample compensation method based on column-control according to successive scans theory. On the basis of our ideas, a small part of pixels of each column are selected as samples, and the column gating time calculated by sample average luminance value of corresponding column is written in hardware program. We adopt the 64 × 32 LEDs display panel as an example to expound the compensation method and obtain good result that the reduction in amplitude of luminance non-uniformity is 65.
View Article and Find Full Text PDFJ Chromatogr A
July 2024
RIC group, President Kennedypark 6, 8500 Kortrijk, Belgium; Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, 9000 Ghent, Belgium. Electronic address:
Monoclonal antibodies (mAbs) are large and highly heterogeneous species typically characterized using a plethora of analytical methodologies. There is a trend within the biopharmaceutical industry to combine several of these methods in one analytical platform to simultaneously assess multiple structural attributes. Here, a protein analyzer for the fully automated middle-up and bottom-up liquid chromatography-mass spectrometry (LC-MS) analysis of charge, size and hydrophobic variants is described.
View Article and Find Full Text PDFEnviron Pollut
March 2024
State Key Laboratory of Water Resources and Hydropower Engineering Science, Wuhan University, Wuhan 430072, China; Ningbo Institute of Digital Twin, Eastern Institute of Technology, Ningbo 315200, China. Electronic address:
The in situ biosequestration of Cr(VI) in groundwater with molasses as the carbon source was studied based on column experiments and model simulation in this study. Compared with biological reduction, molasses-based chemical reduction did not cause significant Cr(VI) removal at molasses concentration as high as 1.14 g L.
View Article and Find Full Text PDFAnal Chim Acta
December 2023
Separation Science Group, Department of Organic and Macromolecular Chemistry, Krijgslaan 281, Ghent, Belgium. Electronic address:
Temperature-responsive liquid chromatography (TRLC) offers an alternative for retention and selectivity optimisation in HPLC. This approach thereby exploits temperature gradients on stimuli-responsive stationary phases and forfeits the necessity for solvent gradients, allowing analyses to be performed using aqueous mobile phases. Consequently, it can be employed as a green alternative to reversed-phase separations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!