When performing epicardial ablation of ventricular tachycardia (VT), caution must be taken not to damage the coronary arteries. We report a case in which a new, nonfluoroscopic technique for incorporating an accurate, real-time reconstruction of the main coronary vessels into a three-dimensional electroanatomic map was used for epicardial VT ablation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/pace.12984 | DOI Listing |
BMC Cardiovasc Disord
October 2024
Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
Background: An atrial septal defect (ASD) is considered oval-shaped when its shortest diameter is less than 75% of the longest diameter. Research on percutaneous closure of oval-shaped ASDs is limited, with no known reports of non-fluoroscopic closure for this population.
Objective: To assess the effectiveness of non-fluoroscopic percutaneous closure for oval-shaped ASDs.
Circulation
October 2024
Texas Cardiac Arrhythmia Research Foundation, Austin (A.N.).
Background: Evidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining efficacy. However, the lack of a fully integrated mapping system, a staple technology of most modern electrophysiology procedures, poses limitations in lesion creation and workflow options. A novel variable-loop PFA catheter integrated with an electroanatomic mapping system has been developed that allows for real-time nonfluoroscopic procedural guidance and lesion indexing as well as feedback of tissue-to-catheter proximity.
View Article and Find Full Text PDFRev Cardiovasc Med
December 2023
Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, 100037 Beijing, China.
Background: Transcatheter edge-to-edge repair (TEER) of the mitral valve has emerged as an alternative treatment for mitral regurgitation (MR). However, the high radiation exposure during the process has been associated with multiple adverse effects for medical staff. In this study, we assessed the feasibility and safety of TEER performed solely under the echocardiographic (echo) guidance.
View Article and Find Full Text PDFInt J Cardiol
October 2024
Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
Heart Rhythm
August 2024
Division of Cardiovascular Medicine, University of Iowa Hospitals and Clinics, Iowa City, Iowa. Electronic address: