Sinogram-based coil selection for streak artifact reduction in undersampled radial real-time magnetic resonance imaging.

Quant Imaging Med Surg

Max Planck Institute for Biophysical Chemistry, 37070 Göttingen, Germany;; DZHK (German Center for Cardiovascular Research), partner site Göttingen, Göttingen, Germany.

Published: October 2016

Background: Streak artifacts are a common problem in radial magnetic resonance imaging (MRI). We therefore developed a method for automatically excluding receiver coil elements which lead to these artifacts.

Methods: The proposed coil selection relates to real-time MRI data based on highly undersampled radial acquisitions. It exploits differences between high- and low-resolution sinograms reconstructed from datasets acquired during preparatory scans. Apart from phantom validations, the performance was assessed for real-time MRI studies of different human organ systems in vivo.

Results: The algorithm greatly reduces streak artifact strength without compromising image quality in other parts of the image. It is robust with respect to different experimental settings and fast to be included in the online reconstruction pipeline for real-time MRI.

Conclusions: The proposed method enables a fast reduction of streak artifacts in radial real-time MRI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5130572PMC
http://dx.doi.org/10.21037/qims.2016.10.02DOI Listing

Publication Analysis

Top Keywords

real-time mri
12
coil selection
8
streak artifact
8
undersampled radial
8
radial real-time
8
magnetic resonance
8
resonance imaging
8
streak artifacts
8
real-time
5
sinogram-based coil
4

Similar Publications

Trends in dentomaxillofacial radiology.

World J Radiol

January 2025

Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06500, Türkiye.

Oral and maxillofacial diagnostic imaging is of paramount importance in dental clinical diagnosis, treatment planning, and follow-up procedures. Periapical radiographic examination and numerous panoramic systems are used in routine clinical dental practice. Cone beam CT is widely used and currently the method of choice in oral and maxillofacial implantology, endodontics, maxillofacial surgery, periodontics, degenerative temporomandibular joint disease, orthodontics, airway studies, sleep disorders, and forensic dentistry.

View Article and Find Full Text PDF

Epidemiology, diagnosis and treatment of anterior prostate cancer.

Nat Rev Urol

January 2025

Department of Urology, Guy's and St Thomas' NHS Foundation Trust, London, UK.

Anterior prostate cancers (APCs) are a group of impalpable neoplasms located in regions anterior to the urethra, which comprise the transition zone, apical peripheral zone and anterior fibromuscular stroma. These regions are typically undersampled using conventional biopsy schemes, leading to a low detection rate for APC and a high rate of false negatives. Radical prostatectomy series suggest prevalence rates of at least 10-30%, but transperineal systematic biopsy is ideal for diagnosis, particularly where multiparametric MRI is unavailable.

View Article and Find Full Text PDF

MR imaging of proton beam-induced oxygen depletion.

Med Phys

January 2025

OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.

Background: Previous studies have shown that in-beam magnetic resonance imaging (MRI) can be used to visualize a proton beam during the irradiation of liquid-filled phantoms. The beam energy- and current-dependent local image contrast observed in water was identified to be predominantly caused by beam-induced buoyant convection and associated flow effects. Besides this flow dependency, the MR signal change was found to be characterized by a change in the relaxation time of water, hinting at a radiochemical contribution, which was hypothesized to lie in oxygen depletion-evoked relaxation time lengthening.

View Article and Find Full Text PDF

Swine are increasingly utilized in cardiovascular research due to their anatomical and physiological similarities to humans, particularly for studying diastolic dysfunction. While MRI offers excellent structural imaging, echocardiography provides superior real-time assessment of diastolic parameters. To address the lack of standardized methods and reduce variability across studies, we present a comprehensive guide for performing echocardiography in Yorkshire pigs, detailing anatomical considerations, equipment requirements, and technical approaches.

View Article and Find Full Text PDF

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!