Background And Aims: Terrestrial plant remains in fossilized tree resin are relatively common. However, histology and preservation of plants entombed in Cretaceous ambers remain poorly known. We report an exquisitely preserved conifer leafy axis from 100-million-year-old opaque amber of western France that is assignable to Glenrosa carentonensis Moreau, Néraudeau, Tafforeau & Dépré. The purpose of this paper is to discuss the taphonomy and the use of microtomography for studies of palaeobotanical remains in amber.

Methods: A leafy axis was examined using propagation phase-contrast X-ray synchrotron microtomography with voxel sizes of 14·9, 1·4, and 0·7 μm.

Key Results: The conifer leafy axis described is preserved in three dimensions. Despite desiccation of the specimen within the surrounding amber, the cuticle, as well as most of inner tissues, is preserved in three dimensions down to the cellular level. Epidermis, palisade parenchyma, spongy parenchyma, transfusion tracheids and vascular bundles are clearly distinguished.

Conclusions: Gross morphology and histology of the specimen were revealed using synchrotron microtomography, allowing an unprecedented resolution for the study of soft-bodied plants entombed in amber. The study reveals a peculiar combination of authigenic and duripartic preservation as well as permineralization, and highlights the complexity of taphonomic processes that can occur in amber inclusions. This fossil demonstrates the difficulty of studying amber-preserved plant remains under certain conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5218381PMC
http://dx.doi.org/10.1093/aob/mcw225DOI Listing

Publication Analysis

Top Keywords

synchrotron microtomography
12
leafy axis
12
western france
8
revealed synchrotron
8
plant remains
8
plants entombed
8
conifer leafy
8
preserved three
8
three dimensions
8
amber
5

Similar Publications

Mammalian hearing operates on three basic steps: 1) sound capturing, 2) impedance conversion, and 3) frequency analysis. While these canonical steps are vital for acoustic communication and survival in mammals, they are not unique to them. An equivalent mechanism has been described for katydids (Insecta), and it is unique to this group among invertebrates.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the osteochondral interface, which includes calcified cartilage (CC) and subchondral bone (SCB), and presents a new method for analyzing chondrocyte and osteocyte lacunae in human knee samples using advanced imaging techniques.
  • Researchers employed a combination of a marker-controlled watershed algorithm and deep learning (specifically nnU-Net) to enhance the 3D segmentation of cell lacunae, effectively improving the assessment of their structures.
  • Findings showed that while chondrocyte characteristics didn't differ significantly between control and osteoarthritic knees, osteocytes in the osteoarthritic group exhibited lower anisotropy and tended to be more spherical,
View Article and Find Full Text PDF

Transparent crystalline scintillators such as cerium-doped YAG or LuAG are widely used in X-ray imaging for the indirect detection of X-rays. The application of reflective coatings on the front side to improve the optical gain is common practice for flat panel detectors with CsI or GdOS powder scintillators but still largely unknown for crystalline scintillators such as LuAG. This work shows experimentally and quantitatively how a black and reflective coating on the X-ray side of a 2 mm LuAG:Ce scintillator improves the image quality compared to a 2 mm LuAG:Ce scintillator without a coating.

View Article and Find Full Text PDF
Article Synopsis
  • In X-ray microtomography, flat field images are crucial for normalizing sample projections, but issues arise due to the fast data collection and bulky devices in synchrotron facilities.
  • Researchers developed a deep-learning method using an improved pix2pixHD model to generate flat fields from CT projections, significantly improving the accuracy of artefact correction compared to conventional techniques.
  • The new method not only reduces systematic errors during image normalization but also generalizes well across different low Z material samples, making it effective for dynamic CT imaging of various processes.
View Article and Find Full Text PDF

Fabrication and X-ray microtomography of sandwich-structured PEEK implants for skull defect repair.

Sci Rep

November 2024

Shandong Provincial Engineering and Technical Center of Light Manipulations & Shandong Provincial Key Laboratory of Optics and Photonic Device, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.

Bone defects pose a significant risk to human health. Medical polyetheretherketone (PEEK) is an excellent implant material for bone defect repair, but it faces the challenge of bone osteoconduction and osseointegration. Osteoconduction describes the process by which bone grows on the surface of the implant, while osseointegration is the stable anchoring of the implant achieved by direct contact between the bone and the implant.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!