Background And Aims: Terrestrial plant remains in fossilized tree resin are relatively common. However, histology and preservation of plants entombed in Cretaceous ambers remain poorly known. We report an exquisitely preserved conifer leafy axis from 100-million-year-old opaque amber of western France that is assignable to Glenrosa carentonensis Moreau, Néraudeau, Tafforeau & Dépré. The purpose of this paper is to discuss the taphonomy and the use of microtomography for studies of palaeobotanical remains in amber.
Methods: A leafy axis was examined using propagation phase-contrast X-ray synchrotron microtomography with voxel sizes of 14·9, 1·4, and 0·7 μm.
Key Results: The conifer leafy axis described is preserved in three dimensions. Despite desiccation of the specimen within the surrounding amber, the cuticle, as well as most of inner tissues, is preserved in three dimensions down to the cellular level. Epidermis, palisade parenchyma, spongy parenchyma, transfusion tracheids and vascular bundles are clearly distinguished.
Conclusions: Gross morphology and histology of the specimen were revealed using synchrotron microtomography, allowing an unprecedented resolution for the study of soft-bodied plants entombed in amber. The study reveals a peculiar combination of authigenic and duripartic preservation as well as permineralization, and highlights the complexity of taphonomic processes that can occur in amber inclusions. This fossil demonstrates the difficulty of studying amber-preserved plant remains under certain conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5218381 | PMC |
http://dx.doi.org/10.1093/aob/mcw225 | DOI Listing |
PLoS Comput Biol
December 2024
School of Life and Environmental Sciences, University of Lincoln, Lincoln, United Kingdom.
Mammalian hearing operates on three basic steps: 1) sound capturing, 2) impedance conversion, and 3) frequency analysis. While these canonical steps are vital for acoustic communication and survival in mammals, they are not unique to them. An equivalent mechanism has been described for katydids (Insecta), and it is unique to this group among invertebrates.
View Article and Find Full Text PDFSci Rep
November 2024
Paris Cité University CNRS INSERM, B3OA, UMR 7052, U 1271, 10 avenue de Verdun, Paris, 75010, France.
Transparent crystalline scintillators such as cerium-doped YAG or LuAG are widely used in X-ray imaging for the indirect detection of X-rays. The application of reflective coatings on the front side to improve the optical gain is common practice for flat panel detectors with CsI or GdOS powder scintillators but still largely unknown for crystalline scintillators such as LuAG. This work shows experimentally and quantitatively how a black and reflective coating on the X-ray side of a 2 mm LuAG:Ce scintillator improves the image quality compared to a 2 mm LuAG:Ce scintillator without a coating.
View Article and Find Full Text PDFSci Rep
November 2024
Shandong Provincial Engineering and Technical Center of Light Manipulations & Shandong Provincial Key Laboratory of Optics and Photonic Device, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Bone defects pose a significant risk to human health. Medical polyetheretherketone (PEEK) is an excellent implant material for bone defect repair, but it faces the challenge of bone osteoconduction and osseointegration. Osteoconduction describes the process by which bone grows on the surface of the implant, while osseointegration is the stable anchoring of the implant achieved by direct contact between the bone and the implant.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!