Introduction: Although T1 weighted spin echo (T1W SE) images are widely used to study anatomical details and pathologic abnormalities of the brain, its role in delineation of lesions and reduction of artifacts has not been thoroughly investigated. BLADE is a fairly new technique that has been reported to reduce motion artifacts and improve image quality.
Objective: The primary objective of this study is to compare the quality of T1-weighted fluid attenuated inversion recovery (FLAIR) images with BLADE technique (T1W FLAIR BLADE) and the quality of T1W SE images in the MR imaging of the brain. The goal is to highlight the advantages of the two sequences as well as which one can better reduce flow and motion artifacts so that the imaging of the lesions will not be impaired.
Materials And Methods: Brain examinations with T1W FLAIR BLADE and T1W SE sequences were performed on 48 patients using a 1.5T scanner. These techniques were evaluated by two radiologists based on: a) a qualitative analysis i.e. overall image quality, presence of artifacts, CSF nulling; and b) a quantitative analysis of signal-to-noise ratios (SNR), contrast-to-noise ratios (CNR) and Relative Contrast. The statistical analysis was performed using the Kruskal-Wallis non-parametric system.
Results: In the qualitative analysis, BLADE sequences had a higher scoring than the conventional sequences in all the cases. The overall image quality was better on T1W FLAIR BLADE. Motion and flow-related artifacts were lower in T1W FLAIR BLADE. Regarding the SNR measurements, T1W SE appeared to have higher values in the majority of cases, whilst T1W-FLAIR BLADE had higher values in the CNR and Relative Contrast measurements.
Conclusion: T1W FLAIR BLADE sequence appears to be superior to T1W SE in overall image quality and reduction of motion and flow-pulsation artifacts as well as in nulling CSF and has been preferred by the clinicians. T1W FLAIR BLADE may be an alternative approach in brain MRI imaging.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.mri.2016.12.007 | DOI Listing |
Med Phys
December 2024
Department of Radiation Oncology, Emory University, Atlanta, Georgia, USA.
Background: Gadolinium-based contrast agents (GBCAs) are commonly used in MRI scans of patients with gliomas to enhance brain tumor characterization using T1-weighted (T1W) MRI. However, there is growing concern about GBCA toxicity. This study develops a deep-learning framework to generate T1-postcontrast (T1C) from pre-contrast multiparametric MRI.
View Article and Find Full Text PDFPediatr Radiol
December 2024
Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45229, USA.
Background: Diagnostically adequate contrast and spatial resolution in brain MRI require prolonged scan times, leading to motion artifacts and image degradation in awake children. Rapid multi-parametric techniques can produce diagnostic images in awake children, which could help to avoid the need for sedation.
Objective: To evaluate the utility of a rapid echo-planar imaging (EPI)-based multi-inversion spin and gradient echo (MI-SAGE) technique for generating multi-parametric quantitative brain maps and synthetic contrast images in awake pediatric participants.
J Magn Reson Imaging
December 2024
Neuroimaging Unit, Neuroimmunology Division, Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Background: Selective inversion recovery quantitative magnetization transfer (SIR-qMT)-derived macromolecular to free water pool size ratio (PSR) and diffusion tensor imaging (DTI)-derived radial diffusivity (RD) are potential metrics for assessing myelin integrity in multiple sclerosis (MS). However, establishing their accuracy in identifying tissue injury is essential for clinical translation.
Purpose: To compare the accuracy and Cohen's effect size (ES) of PSR and RD in detecting and quantifying tissue injury in early MS.
Invest Radiol
December 2024
From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany (K.K.-J., N.E., E.G., K.S., J.U., H.F.-P., D.S., V.S., J.M.K., I.P., S.H., M.B., M.O.B.); Clinical Cooperation Unit Neurooncology, German Cancer Consortium (DKTK) within the German Cancer Research Center (DKFZ), Heidelberg, Germany (K.K.-J., F.W., W.W.); Department of Neurology, Heidelberg University Hospital and National Center for Tumor Diseases (NCT), Heidelberg, Germany (D.B., F.M.I., F.W., W.W.); DKTK, DKFZ, Clinical Cooperation Unit Neuropathology, Heidelberg, Germany (F.M.I.); Division of Radiology, DKFZ, Heidelberg, Germany (N.V., D.P.); Clinical Cooperation Unit Neuroimmunology and Brain Tumor Immunology, DKTK, DKFZ, Heidelberg, Germany (L.B., M.P., M.O.B.); Department of Neurology, Medical Faculty Mannheim, Mannheim Center for Translational Neurosciences, Heidelberg University, Mannheim, Germany (L.B., M.P.); Division of Neuroradiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA (D.P.); and Clinic for Neuroradiology, University Hospital Bonn, Bonn, Germany (D.P.).
Objectives: Recurrent glioma is highly treatment resistant due to its metabolic, cellular, and molecular heterogeneity and invasiveness. Tumor monitoring by conventional MRI has shortcomings to assess these key glioma characteristics. Recent studies introduced chemical exchange saturation transfer for metabolic imaging in oncology and assessed its diagnostic value for newly diagnosed glioma.
View Article and Find Full Text PDFIntroduction: Deregulation of the cerebrovascular system has been linked to neurodegeneration, part of a putative causal pathway into etiologies such as Alzheimer's disease (AD). In medical imaging, time-of-flight magnetic resonance angiography (TOF-MRA) and perfusion MRI are the most common modalities used to study this system. However, due to lack of resources, many large-scale studies of AD are not acquiring these images; this creates a conundrum, as the lack of evidence limits our knowledge of the interaction between the cerebrovascular system and AD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!