Development of a Rainbow Lateral Flow Immunoassay for the Simultaneous Detection of Four Mycotoxins.

J Agric Food Chem

Faculty of Pharmaceutical Sciences, Department of Bioanalysis, Laboratory of Food Analysis, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium.

Published: August 2017

A multiplex lateral flow immunoassay (LFIA) for the determination of the mycotoxins deoxynivalenol, zearalenone, and T2/HT2-toxin in barley was developed with luminescent quantum dots (QDs) as label. The synthesized QDs were hydrophilized by two strategies, that is, coating with an amphiphilic polymer or silica. The water-soluble QDs were compared with regard to their bioconjugation with monoclonal antibody (mAb) and were tested on a LFIA. Silica-coated QDs that contained epoxy groups were most promising. Therefore, green, orange, and red epoxy-functionalized silica-coated QDs were conjugated with anti-ZEN, anti-DON, and anti-T2 mAb, respectively. The LFIA was developed in accordance with the European Commission legal limits with cutoff limits of 1000, 80, and 80 μg/kg for deoxynivalenol, zearalenone, and T2/HT2-toxin, respectively. The LFIA gave a fast result (15 min) with a low false-negative rate (<5%), and the results were easy to interpret without any sophisticated equipment.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.jafc.6b04157DOI Listing

Publication Analysis

Top Keywords

lateral flow
8
flow immunoassay
8
deoxynivalenol zearalenone
8
zearalenone t2/ht2-toxin
8
silica-coated qds
8
qds
5
development rainbow
4
rainbow lateral
4
immunoassay simultaneous
4
simultaneous detection
4

Similar Publications

Quantitative determination of leptin hormone using gold nanoparticle-based lateral flow assay.

Mikrochim Acta

January 2025

Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, Konya, Türkiye.

A lateral flow assay (LFA) has been developed that can be used in point-of-care (PoC) use for the sensitive determination of leptin hormone. The limit of detection value was 0.158 ng/mL and the limit of quantification value was 0.

View Article and Find Full Text PDF

Background: Adrenaline and glucose are essential biomarkers in human body for maintaining metabolic balance. Abnormal levels of adrenaline and glucose are associated with various diseases. Therefore, it is important to design portable, on-site devices for rapid adrenaline and glucose analysis to safeguard health.

View Article and Find Full Text PDF

Lateral flow immunoassay (LFIA) has the advantages of simplicity and rapidness, and is widely used for the rapid detection of pesticides and other analytes. However, small molecule compounds such as pesticides are often analyzed using competitive LFIA (CLFIA), whose sensitivity often does not meet the actual needs. In this study, a noncompetitive LFIA (NLFIA) for deltamethrin (DM) with high sensitivity was developed by using anti-immunocomplex peptides (AIcPs).

View Article and Find Full Text PDF

Coupling tree-ring and geomorphic analyses to reconstruct the 1950s massive Glacier Lake Outburst Flood at Grosse Glacier, Chilean Patagonia.

Sci Total Environ

January 2025

Climate Change Impacts and Risks in the Anthropocene (C-CIA), Institute for Environmental Sciences, University of Geneva, Geneva, Switzerland; dendrolab.ch, Department of Earth Sciences, University of Geneva, Geneva, Switzerland; Department F.-A. Forel for Environmental and Aquatic Sciences, University of Geneva, Switzerland.

Over recent decades, global warming has led to sustained glacier mass reduction and the formation of glacier lakes dammed by potentially unstable moraines. When such dams break, devastating Glacial Lake Outburst Floods (GLOFs) can occur in high mountain environments with catastrophic effects on populations and infrastructure. To understand the occurrence of GLOFs in space and time, build frequency-magnitude relationships for disaster risk reduction or identify regional links between GLOF frequency and climate warming, comprehensive databases are critically needed.

View Article and Find Full Text PDF

The rapid, sensitive, and accurate detection of paralytic shellfish toxins (PSTs), such as saxitoxin (STX), is critical for protecting human health due to the frequent occurrence of toxic red tides. In this work, to address the low affinity of traditional mouse monoclonal antibodies (m-mAbs), rabbit monoclonal antibodies (r-mAbs) against STX were produced by a single B-cell sorting culture and a cross-selection strategy. The r-mAbs showed 100-fold improvement in sensitivity (IC = 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!