A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An Early Canadian Experience With the Correx Automated Coring and Apical Connector Device for Aortic Valve Bypass. | LitMetric

An Early Canadian Experience With the Correx Automated Coring and Apical Connector Device for Aortic Valve Bypass.

Innovations (Phila)

From the *Schulich School of Medicine, Western University, London, ON Canada; and †Division of Cardiac Surgery, University of Western Ontario, Lawson Health Research Institute, London, ON Canada.

Published: May 2017

Objective: Aortic valve replacement is the standard of care for severe, symptomatic aortic valve stenosis (AS); however, anatomy or pre-existing comorbidities may preclude conventional or alternative transcatheter approaches. Aortic valve bypass (AVB) may be performed as a salvage procedure for the relief of symptomatic aortic stenosis in patients who are not suitable candidates for aortic valve replacement.

Methods: At our institution, seven patients underwent AVB using the Correx automated coring and apical connector system. All patients had severe AS with New York Heart Association functional class 3 symptoms and were not candidates for conventional or transcatheter approaches. Via a left anterolateral thoracotomy to access the descending aorta and left ventricular apex, we used the Correx system (Correx, Waltham, MA USA) to anastomose a valve conduit to the left ventricular apex proximally and the descending aorta distally. Three patients required cardiopulmonary bypass.

Results: In all seven patients, the automated coring and apical connector was successfully deployed. There were two in-hospital deaths in this series. Immediately postoperatively and at 3 months, there was a significant reduction in mean and peak valve gradients, and all surviving patients performed at New York Heart Association functional class 1.

Conclusions: Aortic valve bypass seems to be an acceptable alternative for the treatment of severe AS in high-risk patients who are not candidates for aortic valve replacement. The Correx automated system may improve the clinical applicability and surgical reproducibility of AVB in appropriately selected patients in which conventional or transcatheter aortic valve replacement is not a feasible options.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IMI.0000000000000322DOI Listing

Publication Analysis

Top Keywords

aortic valve
32
correx automated
12
automated coring
12
coring apical
12
apical connector
12
valve bypass
12
valve replacement
12
valve
10
aortic
9
symptomatic aortic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!