Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Unlabelled: Purpose state: Orthotic wearing time may be an important confounder in efficacy studies of treatment in children with spastic cerebral palsy (SCP). Most studies measure parent-reported wearing time (WT) with questionnaires, but it is questionable whether this yields valid results. This study aims to compare WT with objectively measured wearing time (WT) in children with SCP receiving orthotic treatment.
Method: Eight children with SCP participated in this observational study. For one year, they received knee-ankle-foot orthosis (KAFO) treatment. WT was measured using questionnaires. WT was measured using temperature sensor-data-loggers that were attached to the KAFOs. The 2.5th and 97.5th percentiles and median of differences between methods (per participant) were used to calculate limits of agreement and systematic differences.
Results: There was no systematic difference between WT and WT (0.1 h per week), but high inter-individual variation of the difference was found, as reflected by large limits of agreement (lower limit/2.5th percentile: -1.7 h/week; upper limit/97.5th percentile: 11.1 h/week).
Conclusions: Parent-reported wearing time (WTparent) of a KAFO differs largely from objectively measured wearing time (WT) using temperature sensors. Therefore, parent-reported wearing time (WT) of KAFOs should be interpreted with utmost care. Implications for Rehabilitation Low wearing time of orthoses may be a cause of inefficacy of orthotic treatment and incorrect reported wearing time may bias results of efficacy studies. Results of this study show that parent-reported wearing time is not in agreement with objectively measured wearing time. Parent-reported wearing time of KAFOs should be interpreted with utmost care. Objective methods are recommended for measuring orthotic wearing time.