Ventricular Assist Device Implantation Configurations Impact Overall Mechanical Circulatory Support System Thrombogenic Potential.

ASAIO J

From the *Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York; †Department of Surgery, Stony Brook University, Stony Brook, New York; and ‡Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, Arizona.

Published: January 2018

Ventricular assist devices (VADs) became in recent years the standard of care therapy for advanced heart failure with hemodynamic compromise. With the steadily growing population of device recipients, various postimplant complications have been reported, mostly associated with the hypershear generated by VADs that enhance their thrombogenicity by activating platelets. Although VAD design optimization can significantly improve its thromboresistance, the implanted VAD need to be evaluated as part of a system. Several clinical studies indicated that variability in implantation configurations may contribute to the overall system thrombogenicity. Numerical simulations were conducted in the HeartAssist 5 (HA5) and HeartMate II (HMII) VADs in the following implantation configurations: 1) inflow cannula angles: 115° and 140° (HA5); 2) three VAD circumferential orientations: 0°, 30°, and 60° (HA5 and HMII); and 3) 60° and 90° outflow graft anastomotic angles with respect to the ascending aorta (HA5). The stress accumulation of the platelets was calculated along flow trajectories and collapsed into a probability density function, representing the "thrombogenic footprint" of each configuration-a proxy to its thrombogenic potential (TP). The 140° HA5 cannula generated lower TP independent of the circumferential orientation of the VAD. Sixty-degree orientation generated the lowest TP for the HA5 versus 0° for the HMII. An anastomotic angle of 60° resulted in lower TP for HA5. These results demonstrate that optimizing the implantation configuration reduces the overall system TP. Thromboresistance can be enhanced by combining VAD design optimization with the surgical implantation configurations for achieving better clinical outcomes of implanted VADs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5411323PMC
http://dx.doi.org/10.1097/MAT.0000000000000488DOI Listing

Publication Analysis

Top Keywords

implantation configurations
16
ventricular assist
8
thrombogenic potential
8
vad design
8
design optimization
8
140° ha5
8
ha5
7
implantation
5
vad
5
assist device
4

Similar Publications

Unlabelled: The article is devoted to the problem of the rehabilitation stage of cochlear implantation in patients with inner ear abnormalities. It provides a detailed analysis of the audiological characteristics of such patients and draws conclusions about approaches to interpreting diagnostic data and speech processors fitting.

Material And Methods: The track records of 80 patients with abnormalities of the inner ear development were retrospectively studied, of which 10 had abnormal structure of the auditory nerve.

View Article and Find Full Text PDF

This study aimed to develop an algorithm for modelling tooth-tooth or implant-implant support configurations for a given 4-unit fixed partial denture (FPD). : The algorithm was implemented in Rhinoceros/Grasshopper to automatically generate geometries with varying bone loss (0 mm to 3 mm), support type (tooth-tooth and implant-implant support) and bone quality (D1 to D4) for a 4-unit FPD. Afterward, a finite element analysis was carried out with a load applied to the central connector of the FPD.

View Article and Find Full Text PDF

Versatility of Diagon\Gel 4Two Implants in Aesthetic and Reconstructive Breast Surgery.

Aesthetic Plast Surg

December 2024

Plastic Surgeon, Private Practice, Academia de Cirurgia Plàstica, Oporto, Portugal.

Background: Breast augmentation and breast reconstruction with implants are among the most performed surgery worldwide.

Objective: In the search for an ideal implant in terms of safety, shape and consistency, the authors report their experience with a subtype of breast implant, the Diagon\Gel 4Two implants, in both cosmetic and reconstructive cases by analyzing their experience on 116 consecutive patients.

Methods: One hundred and sixteen consecutive patients undergoing both aesthetic and reconstructive breast surgery using Diagon\Gel 4Two Implants between January 2021 and December 2022 were retrospectively reviewed.

View Article and Find Full Text PDF

Optimal parameter setting and evaluation for ultraviolet-assisted direct ink writing bioprinting of nHA/PEGDA scaffold.

Biomed Mater

December 2024

Department of Oral and Maxillofacial Surgery, First Hospital of Shanxi Medical University, Xinjian South Road 85#, Taiyuan, China, Taiyuan, 030001, CHINA.

Ultraviolet-assisted Direct Ink Writing(UV-DIW), an extrusion-based additive manufacturing technology, has emerged as a prominent 3D printing technique and is currently an important topic in bone tissue engineering research. This study focused on the printability of double-network (DN) bioink (Nano-hydroxyapatite/Polyethylene glycol diacrylate(nHA/PEGDA)). Next, we search for the optimal UV-DIW printing parameters for the scaffold formed by nHA-PEGDA.

View Article and Find Full Text PDF

Analyzing Spinal Cord Stimulation With Different Electrode Configurations: A Numerical Study.

Int J Numer Method Biomed Eng

January 2025

Department of Biomedical Engineering, Inonu University, Malatya, Türkiye.

Spinal cord stimulation (SCS) represents a therapeutic approach for chronic pain management in patients refractory to conventional treatments. By implanting electrodes in the epidural space, SCS aims to mitigate pain transmission to the brain through electrical stimulation, often resulting in sensory perceptions such as paresthesia. This study investigates the influence of electrode configurations on electrical parameters, including current density and electric potential, within the spinal cord environment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!