Heat-related deaths of children are most often encountered in the context of enclosed vehicles in summer months. Deviating from this, a 16-month-old boy was found unresponsive in a stroller that was placed adjacent to a space heater during mid-winter. The cause of death was hyperthermia and thermal injuries. Manner of death determination was difficult due to alleged surrounding circumstances. To understand the time-course of this child's injuries, a child death scene investigation was performed; the stroller and space heater were recovered. In a re-enactment of the events, a slaughtered pig approximating the child's size was warmed using a water bath and placed in the stroller beside the space heater. Cutaneous temperature measurements showed rapid initial temperature rise with subsequent steady increases. Tanning of the skin was seen on periodic direct observations. Internal temperature monitoring illustrated steady increases. This experiment was essential in classifying the manner of death as homicide.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1556-4029.13307DOI Listing

Publication Analysis

Top Keywords

space heater
12
hyperthermia thermal
8
thermal injuries
8
manner death
8
stroller space
8
steady increases
8
death
5
injuries death
4
death forced
4
forced convection
4

Similar Publications

This Letter reports what we believe to be a novel schlieren approach with adaptive temporal resolution. The fundamental concept of this approach is to fuse an event-based camera and a low-speed frame-based camera to generate high-frame-rate videos by leveraging the strengths of both. Using a novel experimental setup, events and frames are accurately aligned in both space and time.

View Article and Find Full Text PDF

This paper reports on the experimental demonstration of a fully integrated frequency-modulated continuous-wave (FMCW) LiDAR sensing system, operating at 2.0 µm. It makes use of a widely tunable hybrid external cavity laser based on the combination of GaSb gain chip and silicon waveguide circuits.

View Article and Find Full Text PDF

Heating decoys to mimic thermal signatures of live animals for drones.

MethodsX

December 2024

Department of Wildlife, Fisheries, and Aquaculture, Mississippi State University, Mississippi State, MS 39762, USA.

Thermal sensors mounted on drones (unoccupied aircraft systems) are popular and effective tools for monitoring cryptic animal species, although few studies have quantified sampling error of animal counts from thermal images. Using decoys is one effective strategy to quantify bias and count accuracy; however, plastic decoys do not mimic thermal signatures of representative species. Our objective was to produce heat signatures in animal decoys to realistically match thermal images of live animals obtained from a drone-based sensor.

View Article and Find Full Text PDF

The magnetic cage.

Philos Trans A Math Phys Eng Sci

October 2024

United Kingdom Atomic Energy Authority, Culham Campus, Abingdon, Oxfordshire OX14 3DB, UK.

The Spherical Tokamak for Energy Production (STEP) requires high-field magnet designs and has therefore adopted the REBCO-based high-temperature superconductor (HTS) as its current carrier. The HTS enables the toroidal field (TF) coils to be remountable, which unlocks STEP's vertical maintenance approach; however, remountable joints, approximately 18 GJ of stored energy and limited space down the centre of a spherical tokamak, make the TF coils the most challenging. STEP has pursued a passive approach to TF coil quench protection in order to limit coil terminal voltage.

View Article and Find Full Text PDF

Colorimetric detection of serum creatinine on a miniaturized platform using hue-saturation-value space analysis.

Sci Rep

August 2024

Department of Bioengineering, Faculty of Engineering, Izmir Institute of Technology, Gülbahçe Campus, Block E, Room K1-36, Urla/Izmir, 35430, Türkiye.

Article Synopsis
  • Chronic kidney disease (CKD) is a common and impactful health issue worldwide, but traditional lab methods for assessing serum creatinine are slow and costly, limiting timely diagnoses.
  • This study presents a new compact system that uses an integrated heater and smartphone technology for rapid, accurate serum creatinine measurement, employing the Jaffe method within a microreservoir chip.
  • The innovative, low-cost device (approximately $87) allows for decentralized testing, potentially improving CKD management and accessibility, particularly in areas lacking advanced laboratory facilities.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!