Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Stereoelectroencephalography (SEEG) was developed by Talairach and Bancaud in Paris in the late 1950s. Subsequently, the Talairach methodology was adopted at a number of additional centers in Europe and Canada. Technical aspects remained essentially unchanged for the following 30 years. Only in the last two decades, because of advancements in image-guided surgery systems, robotics, and computer-aided planning, use of SEEG has become more widespread, and reports describing these new developments have been published.
Objectives: This systematic review was designed to assess published reports of SEEG surgical techniques and safety profile.
Data Sources: An electronic search was performed of Medline, Embase, and Scopus databases. In addition, the content pages of several standard epilepsy surgery textbooks were searched. Full-text English studies describing SEEG surgical technique or pertinent epidemiological data were included. Conference abstracts, reviews, posters, editorials, comments, and letters were excluded.
Results: Three hundred fifty-nine of 2,903 potentially eligible studies published by 32 centers were reviewed. Thirty-one of these primarily discussed the surgical technique. Thirty-five major complications (including 4 fatalities) were reported among 4,000 patients (0.8%) implanted with 33,000 electrodes.
Limitations: The number of SEEG patients is likely to be underestimated because only a few groups have exhaustively reported their experience. Moreover, it is possible that a number of teams performing SEEG have not published studies on the topic.
Conclusions: Rigorous SEEG, thanks to its basic principles and updated technologies, is a safe and accurate method to define the epileptogenic zone by means of stereotactically implanted intracerebral electrodes.