The trajectories, referred to as lifelines, of individual microorganisms in an industrial scale fermentor under substrate limiting conditions were studied using an Euler-Lagrange computational fluid dynamics approach. The metabolic response to substrate concentration variations along these lifelines provides deep insight in the dynamic environment inside a large-scale fermentor, from the point of view of the microorganisms themselves. We present a novel methodology to evaluate this metabolic response, based on transitions between metabolic "regimes" that can provide a comprehensive statistical insight in the environmental fluctuations experienced by microorganisms inside an industrial bioreactor. These statistics provide the groundwork for the design of representative scale-down simulators, mimicking substrate variations experimentally. To focus on the methodology we use an industrial fermentation of in a simplified representation, dealing with only glucose gradients, single-phase hydrodynamics, and assuming no limitation in oxygen supply, but reasonably capturing the relevant timescales. Nevertheless, the methodology provides useful insight in the relation between flow and component fluctuation timescales that are expected to hold in physically more thorough simulations. Microorganisms experience substrate fluctuations at timescales of seconds, in the order of magnitude of the global circulation time. Such rapid fluctuations should be replicated in truly industrially representative scale-down simulators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5129516PMC
http://dx.doi.org/10.1002/elsc.201600061DOI Listing

Publication Analysis

Top Keywords

euler-lagrange computational
8
computational fluid
8
fluid dynamics
8
metabolic response
8
representative scale-down
8
scale-down simulators
8
dynamics bioreactor
4
bioreactor scale
4
scale analysis
4
analysis organism
4

Similar Publications

The transmission of virus-containing droplets among multiple people in an outdoor environment is seldom evaluated. In this study, an Euler-Lagrange computational fluid dynamics approach was used to investigate the effects of evaporation and the body thermal plume on the dispersion of coughed droplets under various wind conditions, and the infection risk was evaluated for various arrangements of individuals queuing outdoors using virtual manikin models. The evaporation time was longer for larger droplets and in a more humid environment.

View Article and Find Full Text PDF

Control of the family of systems that can be represented in the Euler Lagrange (EL) form is both challenging from a theoretical perspective and applicable to a broad spectrum of real systems. For this type of control problem, given that any parameter estimation error and disturbances are not directly addressed, the system performance deteriorates, and stability cannot be deduced in advance. Considering these issues, this work presents the design and the corresponding analysis of a saturation function based, model-free, continuous robust controller for mechanical systems represented in the EL form.

View Article and Find Full Text PDF

Large-scale fermentations (»100 m³) often encounter concentration gradients which may significantly affect microbial activities and production performance. Reliably investigating such scenarios in silico would allow to optimize bioproduction. But related simulations are very rare in particular for large bubble columns.

View Article and Find Full Text PDF

Discrete-time optimal control problems are a crucial type of control problems that deal with a dynamic system evolving in discrete time-steps. This paper introduces a new technique for solving linear discrete-time optimal control problems with state delays, applicable to both finite and infinite time horizons. Our method employs a Riccati matrix equation, optimizing control strategies and ensuring system stability through bounded control inputs.

View Article and Find Full Text PDF

Background: High-efficient pesticide application equipment for protected cultivation is scarce. In response, a fixed-pipe twin-fluid clod fogger (FTCF) was proposed as a potential solution. To investigate the optimal nozzle layout and spray performance, a computational fluid dynamics (CFD) model was used to study the airflow distribution and spray deposition of a FTCF with different nozzle settings using the Euler-Lagrange approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?