A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical Validation of Androgen Receptor Splice Variant 7 Detection in a Clinical Laboratory Improvement Amendments (CLIA) Laboratory Setting. | LitMetric

Patients with castration-resistant prostate cancer (CRPC) often are treated with drugs that target the androgen receptor (AR) ligand-binding domain. Constitutively active AR splice variant 7 (AR-V7) lacks the ligand-binding domain and, if detected in circulating tumor cells, may be associated with resistance to these agents. We validated an AR-V7 assay in a Clinical Laboratory Improvement Amendments (CLIA)-certified laboratory. Circulating tumor cells were isolated, and mRNA was reverse-transcribed into cDNA. Real-time quantitative PCR amplification of reference transcripts (beta-actin and glyceraldehyde-3-phosphate dehydrogenase), prostate-specific transcripts (prostate-specific membrane antigen, prostate-specific antigen, and AR-full length), and AR-V7 was performed. Specimens for validation included an AR-V7 expressing prostate cancer (LNCaP95), 38 peripheral blood controls, and 21 blood samples from CRPC patients. The assay detected as few as five LNCaP95 cells spiked into peripheral blood, showing high analytical sensitivity. Multiple inter-run and intrarun replicates of LNCaP95 cell line experiments yielded similar cycle threshold values for all genes, showing high analytical precision (AR-V7 cycle threshold CV of 0.67%). All 38 healthy control samples were negative for AR-V7, showing high diagnostic specificity (100%). The diagnostic accuracy was confirmed by concurrent testing of 21 CRPC samples in the research laboratory and the clinical diagnostic laboratory: concordance in AR-V7 status was achieved in all cases (positive in 4, negative in 17) (100% accuracy). This first validated clinical assay detects the AR-V7 with high analytical sensitivity, precision, specificity, and accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmoldx.2016.08.003DOI Listing

Publication Analysis

Top Keywords

showing high
12
high analytical
12
androgen receptor
8
splice variant
8
clinical laboratory
8
laboratory improvement
8
improvement amendments
8
prostate cancer
8
ligand-binding domain
8
ar-v7
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!