A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy and reproducibility of KeraScanner analysis in PERK corneal topography. PERK Study Group. | LitMetric

The measurement of the corneal radius of curvature centrally and in the corneal periphery is exceedingly difficult because of variables in photography and data acquisition. We present a technique of Automated image scanning of corneal photographs which provides a more accurate and reproducible analysis of the paracentral corneal contour. We analyzed the sources of error of corneal topography measurement. CorneaScope photographs of calibration balls were generated by each Prospective Evaluation of Radial Keratotomy (PERK) Surgical Center. The 90% confidence intervals for individual ring-radial positions on the 8.00 and 10.00 mm balls were 7.91 to 8.09 mm and 9.89 to 10.11 mm respectively. Our isopter method of analysis for clinical comparison averages all eight radii of curvature for each CorneaScopef ring. This isopter technique reduces the corresponding 90% confidence intervals to 7.96 to 8.03 and 9.95 to 10.06 mm. The measurement variability of a 10 mm calibration ball decreased in the following order: calibration ball positioning, scanner personnel, photograph movement between scans, and nonrepositioned scanning. Photographs of calibration balls demonstrate +/- 4 microns of measurement resolution and patient corneal photographs may be evaluated to +/- 40 microns. This automated scanning system provides consistent data when digitizing keratographs.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02713688909025800DOI Listing

Publication Analysis

Top Keywords

corneal topography
8
corneal photographs
8
photographs calibration
8
calibration balls
8
90% confidence
8
confidence intervals
8
calibration ball
8
+/- microns
8
corneal
7
accuracy reproducibility
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!